10.4.26 Query Output Type
Command = QT <Output Number>
Output Number = <Byte> 1 - 38
Response = <Output Type>
Output Type = <Byte> 0 or 1 (0 = NO, 1 = NC)
10.4.27 Update Output Type
Command = UT <Output Number> <Output Type>
Output Number = <Byte> 1 - 38
Output Type = <Byte> 0 or 1 (0 = NO, 1 = NC)
Response: None (Just header and trailer)
NOTE: UT changes are not allowed while a process is running.
10.4.28 Query User Message
Command = QV <User Message Number>
User Message Number = <Byte> 1 - 10
Response = < User Message>
User Message = <String> Up to 19 characters, null terminated
10.4.29 Update User Message
Command = UV < User Message Number> < User Message Name>
User Message Number = <Byte> 1 - 10
User Message # Name = <String> Up to 19 characters, null terminated
Response = None (Just header and trailer)
NOTE: A user message that is currently displayed will not be changed on the