INFICON IC6 Thin Film Deposition Controller User Manual

Page 218

Advertising
background image

10 - 48

PN

07

4-

50

5-

P1

F

IC6 Operating Manual

13

(0x0d)

Start Timer <Timer>

<Byte>

Timer Range is 1-20

14

(0x0e)

Cancel Timer

<Timer>

<Byte>

Timer Range is 0-20

0 = All

15

(0x0f)

Clock Hold On

<Material>

<Byte>

Stops timer in Pre-Deposit or Post-Deposit. Keeps in current

state at current power setting.

Material Range 0-32 (0 = all materials)

16 (0x10)

Clock Hold Off

<Material>

<Byte>

Restarts timer in Pre-Deposit or Post-Deposit

Material Range 0-32 (0 = all materials)

17

(0x11)

User message on

<Message #>

<Byte>

Message Range is 1-10

18

(0x12)

User message off

<Message #>

<Byte>

Message Range is 1-10

19

(0x13)

Soak Hold 1 on

<Material>

<Byte>

Material Range is 0-32

(0 = all materials)

20

(0x14)

Soak Hold 1 off

<Material>

<Byte>

Material Range is 0-32

(0 = all materials)

21

(0x15)

Soak Hold 2 on

<Material>

<Byte>

Material Range is 0-32

(0 = all materials)

22

(0x16)

Soak Hold 2 off

<Material>

<Byte>

Material Range is 0-32

(0 = all materials)

23

(0x17)

Switch

Sensor<Sensor #> to

<Crystal #>

<Byte><Byte>

Sensor Range = 1 - 8

Crystal Range = 0 to maximum allowed crystals for the

requested sensor. If Crystal # = 0, will switch to the "next"

crystal. If the sensor is not used in a layer currently running, the

next crystal will be the next one in the sequence. If the sensor

is used in a layer that is running, the next crystal will be the next

one from the XL Position parameters sequence. If a sensor is

used in a layer that is running, the value of "Crystal #" must be

zero, otherwise, an error will occur.

24

(0x18)

Clear Failed Crystals

X

<Byte>

Clears all failed crystals except the current crystal for the

requested sensor. X = Sensor

25

(0x19)

Reserved for future use.

26

(0x1a)

Rotate head X

<Byte>

If the requested sensor is a multi crystal sensor and the IC6 is

in Ready, Stop or all active layers are in Idle or Suspend, the

sensor head will rotate. X = Sensor

27

(0x1b)

Default all

Parameters

Sets all parameters except the communication parameters to

default values.

Table 10-15 Remote general (continued)

RG

Command

ID

Meaning

Action Value

Notes

Advertising