Programming and Parameters

Chapter 2

862

867

872

877

882

887

BitSwap 1B Data

BitSwap 2B Data

BitSwap 3B Data

BitSwap 4B Data

BitSwap 5B Data

BitSwap 6B Data

This parameter contains the word from which the replacement bit will be selected. Only the selected bit is
passed to

Par 864

[BitSwap 1 Result].

Default:
Min/Max:

0
32 bits of data

Y

RW 32-bit

Boolean

863

868

873

878

883

888

BitSwap 1B Bit

BitSwap 2B Bit

BitSwap 3B Bit

BitSwap 4B Bit

BitSwap 5B Bit

BitSwap 6B Bit

This parameter specifies the bit from

Par 862

[BitSwap 1B Data] that will replace the specified bit in

Par 860

[BitSwap 1A Data] and be loaded to

Par 864

[BitSwap 1 Result]. A negative bit selection may be used to invert

the data. Use “-32” to invert the value of bit 0.

Default:
Min/Max:

0
-32/+31

RW 16-bit

Integer

864

869

874

879

884

889

BitSwap 1 Result

BitSwap 2 Result

BitSwap 3 Result

BitSwap 4 Result

BitSwap 5 Result

BitSwap 6 Result

This parameter contains the result of the Bit Swap operation.

Default:
Min/Max:

0
32 bits of data

RO 32-bit

Boolean

892

SL Comm TP Sel

Enter or write a value to select SynchLink™ data displayed by

Par 893

[SL Comm TP Data].

Default:

Options:

0 =

0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
9 =
10 =
11 =
12 =

“Zero”

“Zero”

13 = “BufSeqErrTim”

“SL MultA Src”

14 = “Rx Sys Rev”

“SL Mult A In”

15 = “Tx Axis Size”

“SL Mult B In”

16 = “Tx Dir Size”

“SL Mult Out”

17 = “Tx Buf Size”

“Rx Axis Size”

18 = “Tx Pkg Size”

“Rx Dir Size”

19 = “Tx Seq Cnt”

“Rx Buf Size”

20 = “Tx Index 0”

“Rx Pkg Size”

21 = “Tx Index 1”

“Rx Seq Cnt”

22 = “Tx Index 2”

“Rx Index 0”

23 = “Rx Vendor ID”

“Rx Index 1”

24 = “Rx ModuleTyp”

“Rx Index 2”

25 = “Rx Serial #”

893

SL Comm TP Data

Displays data selected by

Par 892

[SL Comm TP Sel].

Default:
Min/Max:

0
-/+2147483648

RO 32-bit

Integer

894

SL CRC Err Accum

Displays the total accumulated number of Cycle Redundancy Check (CRC) errors. Clearing a fault resets this
accumulator. This data is visible on the SynchLink diagnostics tab of the Peer Communication window. Refer to
the SynchLink System Design Guide,
publication 1756-TD008, for PowerFlex 700S SynchLink topologies, hardware and
wiring details.

Default:
Min/Max:

0
0/4294967296

RO 32-bit

Integer

895 SL

CRC

Error

Displays the number of CRC errors that occurred during the last test (last 8 ms). This data is visible on the
SynchLink diagnostics tab of the Peer Communication window.

Default:
Min/Max:

0
0/4294967296

RO 32-bit

Integer

896

SL BOF Err Accum

Displays the total accumulated number of Beginning of Frame (BOF) errors. Clearing a fault resets this
accumulator. This data is visible on the SynchLink diagnostics tab of the Peer Communication window.

Default:
Min/Max:

0
0/4294967296

RO 32-bit

Integer

897

SL BOF Error

Displays the number of BOF errors that occurred during the last test (last 8 ms). This data is visible on the
SynchLink diagnostics tab of the Peer Communication window.

Default:
Min/Max:

0
0/4294967296

RO 32-bit

Integer

898

SL CRC Err Limit

Identifies the number of CRC errors per test (per 8 ms) allowed before the drive declares a SynchLink CRC Error
exception event. Set this limit on the SynchLink diagnostics tab of the Peer Communication window.

Default:
Min/Max:

2
0/256

RW 32-bit

Integer

899

SL BOF Err Limit

The number of BOF errors per test (per 8 ms) allowed before the drive declares a SynchLink BOF Error exception
event. Set this limit on the SynchLink diagnostics tab of the Peer Communication window.

Default:
Min/Max:

2
0/256

RW 32-bit

Integer

900 SynchLink

Rev

Indicates the current revision of the local SynchLink Programmable Logic firmware.

Default:
Min/Max:

0.1
0.1/999.9

RO 16-bit

Integer

901

SL System Rev

Indicates the system revision of the SynchLink network. To be compatible on the network, all nodes must have
the same major revision.

Default:
Min/Max:

0.001
0.001/999.999

RO 32-bit

Integer

No.

Name
Description

Values

Link

able

Re

ad

-Write

Da

ta

T

yp

e

A

A

A

A

A

A

Advertising