98

Rockwell Automation Publication 20D-PM001C-EN-P - July 2013

Chapter 2

Programming and Parameters

590

RsTempCoefAdjust

The value specified in this parameter adjusts the temperature compensation coefficient which is calculated
based on the Slip regulator output. A value of 4096 in this parameter doubles the compensation coefficient.
Notes: This value should not be changed. This parameter was added for firmware version 4.001.

Default:
Min/Max:

0
+/-32767

RW 16-bit

Integer

591

RsTmpCoefAdjstEn

A value of “1” in this parameter enables the temperature compensation function in flux and torque estimate
calculation, where the temperature information is based on the Slip regulator output. A value of “0” in this
parameter disables the temperature compensation function.
Notes: This value should not be changed. This parameter was added for firmware version 4.001.

Default:
Min/Max:

0
+/-32767

RW 16-bit

Integer

592

VqsReg On Hystr

For Future Use.
Note: This parameter was added for firmware version 4.001.

Default:
Min/Max:

0
+/-32767

RW 16-bit

Integer

593

SlipReg On Hystr

For Future Use.
Note: This parameter was added for firmware version 4.001.

Default:
Min/Max:

0
-/+32767

RW 16-bit

Integer

594

Nth Torq Compen

Defines harmonic frequency as <n> times mechanical frequency.
Note: This parameter was added for firmware version 5.002.

Default:
Min/Max:

0
0/1000

RW 16-bit

Integer

595

Nth Amplitude

Defines the compensation current amplitude for the Nth harmonic component.
Note: This parameter was added for firmware version 5.002.

Default:
Min/Max:
Scaling:

0
0/4096
4096/

Par 2

[Motor NP FLA]

RW 16-bit

Integer

596

Nth Phase Shift

Defines the phase shift for the Nth harmonic component.
Note: This parameter was added for firmware version 5.002.

Default:
Min/Max:
Scaling:

0
-/+16384
16384/360 deg

RW 16-bit

Integer

597

Mth Torq Compen

Defines harmonic frequency as <m> times mechanical frequency.
Note: This parameter was added for firmware version 5.002.

Default:
Min/Max:

0
0/1000

RW 16-bit

Integer

598

Mth Amplitude

Defines the compensation current amplitude for the Mth harmonic component.
Note: This parameter was added for firmware version 5.002.

Default:
Min/Max:
Scaling:

0
0/4096
4096/

Par 2

[Motor NP FLA]

RW 16-bit

Integer

599

Mth Phase Shift

Defines the phase shift for the Mth harmonic component.
Note: This parameter was added for firmware version 5.002.

Default:
Min/Max:
Scaling:

0
-/+16384
16384/360 deg

RW 16-bit

Integer

600 Lgx

Comm

Format

Indicates the Controller to Drive communication format.
Note: Option values 1…15 and 20…31 are “Reserved”

Default:

Options:

16 =

0 =
16 =
17 =

“Speed Ctrl”

“Not Used”

18 = “UserDefin 1”

“Speed Ctrl”

19 = “Motion”

“PositionCtrl”

32 = “CustmUserDef”

601

From DL DataType

Sets the type of data for each word communicated from DriveLogix™ to the PowerFlex 700S drive. Setting a bit High will configure the associated word as a Real data type and setting the bit Low will
configure it for Integer data type.

602

to

622

FromDriveLogix00

to

FromDriveLogix20

These parameters display the input values communicated from the DriveLogix controller to the PowerFlex 700S
drive.

Default:
Min/Max:

0
-/+32 (dependant on Par 601 [From DL
DataType])

RO 32-bit

Integer

625

To DL DataType

Sets the data type for each word communicated from the PowerFlex 700S drive to DriveLogix. Setting a bit High will configure the associated word as a Real data type and setting the bit Low will
configure it for Integer data type.

No.

Name
Description

Values

Link

able

Re

ad

-Write

Da

ta

T

yp

e

A

A

A

A

A

A

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

DL

20

R

ea

l

DL

19

R

ea

l

DL

18

R

ea

l

DL

17

R

ea

l

DL

16

R

ea

l

DL

15

R

ea

l

DL

14

R

ea

l

DL

13

R

ea

l

DL

12

R

ea

l

DL

11

R

ea

l

DL

10

R

ea

l

DL

09

R

ea

l

DL

08

R

ea

l

DL

07

R

ea

l

DL

06

R

ea

l

DL

05

R

ea

l

DL

04

R

ea

l

DL

03

R

ea

l

DL

02

R

ea

l

DL

01

R

ea

l

DL

00

R

ea

l

Default

x

x

x

x

x

x

x

x

x

x

x

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

DL 2

0 Re

al

DL 1

9 Re

al

DL 1

8 Re

al

DL 1

7 Re

al

DL 1

6 Re

al

DL 1

5 Re

al

DL 1

4 Re

al

DL 1

3 Re

al

DL 1

2 Re

al

DL 1

1 Re

al

DL 1

0 Re

al

DL 0

9 Re

al

DL 0

8 Re

al

DL 0

7 Re

al

DL 0

6 Re

al

DL 0

5 Re

al

DL 0

4 Re

al

DL 0

3 Re

al

DL 0

2 Re

al

DL 0

1 Re

al

DL 0

0 Re

al

Default

x

x

x

x

x

x

x

x

x

x

x

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

Advertising