270

Reslvr0 TP Sel

Enter or write a value to select Fault data displayed in

Par 271

[Reslvr0 TP Data].

Default:

Options:

0 =

0 =
1 =
2 =
3 =

“Zero”

“Zero”

4 = “R0 EPR”

“R0 Edge Time”

5 = “R0 Edge Mode”

“R0 dEdge”

6 = “R0 nMax”

“R0 dTime”

7 = “R0 Delta2Err”

271

Reslvr0 TP Data

Displays the data selected by

Par 270

[Reslvr0 TP Sel].

Default:
Min/Max:

0
-/+2147483648

RO 32-bit

Integer

272 Reslvr0

SpdRatio

Specifies the speed ratio for the resolver option card port 0. The speed ratio comes from the following formula.
Speed ratio = electrical revolutions / mechanical revolutions = pole count / 2.
Note: Option 0 = “Zero” was added for firmware version 2.004.

Default:

Options:

1 =

0 =
1 =
2 =

2 poles (x1)

“Zero”

3 = 6 Poles (x3)

2 Poles (x1)

4 = 8 Poles (x4)

4 Poles (x2)

5 = 10 Poles(x5)

273 Reslvr0

Carrier

Specifies the resolver carrier frequency for the resolver option card port 0.

Default:
Min/Max:
Units:

0
0/10000
Hz

RO 32-bit

Integer

274

Reslvr0 In Volts

Specifies the resolver input voltage for the resolver option card port 0.

Default:
Min/Max:
Units:

0.0000
0.0000/31.0810
V

RO Real

275 Rslvr0

XfrmRatio

Specifies the resolver transform ratio for the resolver option card port 0.

Default:
Min/Max:

0.0000
0.0000/4.0950

RO Real

276 Reslvr0

CableBal

Specifies the resolver cable balance for the resolver option card port 0.

Default:
Min/Max:

0
0/255

RO Real

277

Reslvr0 Type Sel

Specifies used resolver.
The values for options 5 & 12 were changed to “Reserved” for firmware version 2.004. Added options 15 and 16
for firmware version 4.001 but are not functional (for future use).

Default:

Options:

0 =

0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =

“Disabled”

“Disabled”

9 = “1326Ax 460v”

“T2014/2087x1”

10 = “Reserved”

“T2014/2087x2”

11 = “Reserved”

“T2014/2087x5”

12 = “Reserved”

“MPL 460v”

13 = “Reserved”

“Reserved”

14 = “AmciR11XC107”

“Siemens 1FT6”

15 = “PowerTec R1”

“PrkrHn ZX600”

16 = “PowerTec R2”

“Reserved”

No.

Name
Description

Values