Control logic, T as k 3 ), En ab le circ u it – Rockwell Automation 20D PowerFlex 700S AC Drives with Phase II Control Programming Manual User Manual

Page 185

Advertising
background image

Rockwell Automation Publication 20D-PM001C-EN-P - July 2013

185

Control Block Diagrams

Appendix C

control_logic.eps

Control Logic

(T

as

k 3

)

Logic P

a

rs

er

Drv Mo

u

nted

HIM

Extern

a

l DPI

Connection

A

u

x.

Extern

a

l DPI

Connection

Intern

a

l

DPI Comm

Device

Digit

a

l

Inp

u

ts

from

DriveLogix

M

as

k

s

Owner

s

602

151

152

158

0

15

0

15

0

15

0

15

0

15

0

15

31

0

15

FromDriveLogix

00

Logic Comm

a

nd

Applied LogicCmd

Drive Logic R

s

lt

0

31

15

Port 7

Port 0

Port 3

Port 5

Port 2

Port 1

1

2

3

4

5

6

B

A

D

C

F

E

H

G

I

0

15

0

1

Dig In

1

High (

1

)

825

Dig In

1

S

el

v

a

l =

"En

ab

le

"

824

01

0

1

Dig In

2

High (

1

)

826

Dig In

2

S

el

v

a

l =

"En

ab

le

"

824

02

0

1

Dig In

3

High (

1

)

827

Dig In

3

S

el

v

a

l =

"En

ab

le

"

824

03

0

1

Dig In

4

High (

1

)

828

Dig In

4

S

el

v

a

l =

"En

ab

le

"

824

04

0

1

Dig In

5

High (

1

)

829

Dig In

5

S

el

v

a

l =

"En

ab

le

"

824

05

0

1

Dig In

6

High (

1

)

830

Dig In

6

S

el

v

a

l =

"En

ab

le

"

824

06

&

to

S

oftw

a

re

En

ab

le Control

155

15

Logic

S

ta

tus

[E

n

ab

le On

]

155

21

Logic

S

ta

tus

[Hw En

ab

le

On

]

Byp

ass

Hw En

ab

le

J

u

mper

824

00

Loc

a

l I

/O

S

ta

tus

[Hw En

b

l Byp

s

]

When p

824

b

it 0 i

s

low,

p

830

is

not

a

v

a

ilab

le

a

nd

Dig In

6

is

us

ed for H

a

rdw

a

re En

ab

le excl

us

ively

to H

a

rdw

a

re En

ab

le Circ

u

it

En

ab

le Circ

u

it

Logic M

as

k

S

ta

rt M

as

k

Jog M

as

k

Direction M

as

k

F

au

lt Clr M

as

k

670

671

672

673

674

S

top Owner

S

ta

rt Owner

Jog Owner

Direction Owner

F

au

lt Clr Owner

677

678

679

680

681

Norm

a

l

S

top

S

ta

rt

Jog 1

Cle

a

r F

au

lt

Forw

a

rd

Rever

s

e

Re

s

erved

Jog 2

C

u

rrLim

S

top

Co

as

t

S

top

Re

s

erved

Re

s

erved

S

pd Ref

S

el

0

S

pd Ref

S

el

1

S

pd Ref

S

el

2

Re

s

erved

b

00

b

01

b

02

b

03

b

04

b

05

b

06

b

07

b

08

b

09

b

10

b

11

b

12

b

13

b

14

b

15

S

pdR

a

mp D

sb

l

S

pd

S

Crv En

T

a

chLo

ss

R

s

t

Time Axi

s

En

S

pdR

a

mp Hold

S

Reg IntgHld

S

Reg IntgR

s

t

Re

s

erved

Re

s

erved

Ext Flt

/Alm

Inerti

a

Comp

Frict Comp

PI Trim En

Po

s

ition En

PI Trim Hold

PI Triim R

s

t

b

00

b

01

b

02

b

03

b

04

b

05

b

06

b

07

b

08

b

09

b

10

b

11

b

12

b

13

b

14

b

15

Norm

a

l

S

top

S

ta

rt

Jog 1

Cle

a

r F

au

lt

Forw

a

rd

Rever

s

e

Re

s

erved

Jog 2

C

u

rrLim

S

top

Co

as

t

S

top

Re

s

erved

Re

s

erved

S

pd Ref

S

el

0

S

pd Ref

S

el

1

S

pd Ref

S

el

2

Re

s

erved

b

16

b

17

b

18

b

19

b

20

b

21

b

22

b

23

b

24

b

25

b

26

b

27

b

28

b

29

b

30

b

31

S

pdR

a

mp D

sb

l

S

pd

S

Crv En

T

a

chLo

ss

R

s

t

Time Axi

s

En

S

pdR

a

mp Hold

S

Reg IntgHld

S

Reg IntgR

s

t

Re

s

erved

Re

s

erved

Ext Flt

/Alm

Inerti

a

Comp

Frict Comp

PI Trim En

Po

s

ition En

PI Trim Hold

PI Triim R

s

t

b

00

b

01

b

02

b

03

b

04

b

05

b

06

b

07

b

08

b

09

b

10

b

11

b

12

b

13

b

14

b

15

Note

:

The following p

a

ra

meter

s

a

re typic

a

lly referenced

when config

u

ring or monitoring Control Logic

;

p

155 [

Logic

S

ta

tus

]

p

156 [

S

ta

rt Inhi

b

it

s

]

Te

s

tPoint

s

P

161 Logic

TP

S

el

P

162 Logic

TP

D

a

ta

Advertising