Diagnostics menu, Parameter menu, Device select menu – Rockwell Automation 20D PowerFlex 700S AC Drives with Phase II Control Programming Manual User Manual

Page 157: Memory storage menu, Start up menu

Advertising
background image

Rockwell Automation Publication 20D-PM001C-EN-P - July 2013

157

Human Interface Module Overview

Appendix A

Diagnostics Menu

When a fault trips the drive, use this menu to access detailed data about the drive.

Parameter Menu

Refer to View and Edit Parameters on page

158

.

Device Select Menu

Use this menu to access parameters in connected peripheral devices.

Memory Storage Menu

Drive data can be saved to, or recalled from, the HIM or EEPROM. EEPROM is
permanent non-volatile drive memory. HIM sets are files stored in permanent
non-volatile HIM memory.

Start Up Menu

See

Figure 1

on page

16

.

Option

Description

Faults

View the fault queue or fault information, clear faults or resets the drive.

Status Info

View parameters that display status information about the drive.

Device Version

View the firmware version and hardware series of components.

HIM Version

View the firmware version and hardware series of the HIM.

Option

Description

HIM Copycat
Device -> HIM
Device <- HIM

Save data to a HIM set, load data from a HIM set to active drive memory or delete a HIM set.

EEPROM

Save data to EEPROM, load data from EEPROM to active drive memory or name a User set.

Reset To Defaults

Restore the drive to its factory-default settings.

IMPORTANT

When loading data from a HIM set via the Copycat function, values for
parameters 81 [Spd Reg P Gain] and 82 [Spd Reg I Gain] are re-calculated and
overwritten due to parameter 90 [Spd Reg BW] being set to the default value
of “10”. To avoid overwriting the values of parameters 81 and 82, record the
values before performing the Copycat from a HIM to the drive, manually
update the values after the download and set parameter 90 to “0”.