Appendix C

Control Block Diagrams

Diagram Conventions and
Definitions

Definitions of the Per Unit system:
1.0 PU Position = Distance traveled / 1 sec at Base Spd
1.0 PU Speed = Base Speed of the Motor
1.0 PU Torque = Base Torque of the Motor

Task 1

Task 3

Task 2

0 .5 mS

8 .0 mS

2 .0 mS

0 .5 mS

1 .0 mS

0 .25 mS

1 .0 mS

8 .0 mS

8 .0 mS

148

FW TaskTime Actl

val = 0

val = 2

val = 1

FW TaskTime Sel

146

Processor Task time selection:.

NOTE: Faster Task time selections may require
program functions to be disabled to stay within
processor load capabilities.

( ) = Enumerated Parameter
[ ] = Page and Coordinate

ex. 3A2 = pg 3, Column A, Row 2
= Constant value

Read Only Parameter with Bit Enumeration

Read / Write Parameter with Bit Enumeration

Provides additional information

Read Only Parameter

Read / Write Parameter

Symbols:

* Notes, Important :

(1) Parameter 147 [FW Functions EN] is used to
activate and deactivate firmware functions. The
PowerFlex 700S drives ships with the position
regulator deactivated. To enable the position
regulator, set Parameter 147, bit 16 to 1 “On”.
(2) Parameter 1000 [UserFunct Enable] is used to
activate and deactivate the User Functions.
(3) These diagrams are for reference only and may
not accurately reflect all logical control signals;
actual functionality is implied by the
approximated diagrams. Accuracy of these
diagrams is not guaranteed.