Rockwell Automation Publication 20D-PM001C-EN-P - July 2013

29

Programming and Parameters

Chapter 2

User F

unction

s

Inputs & O

utputs

Comm

unication

Utility

Speed/P

osit Fd

bk

Position Control

Proce

ss Control

Torque Control

Speed Control

Dynamic

Control

Motor Control

Monitor

Peak Detection

210
211
212
213
214
215
216
217
218
219

PeakDtct Ctrl In
PeakDtct Status
PkDtct1 In DInt
PkDtct1 In Real
PeakDtct1 Preset
PeakDetect1 Out
PkDtct2 In DInt
PkDtct2 In Real
PeakDtct2 Preset
PeakDetect2 Out

Diagnostics

155
156
304
824
320
321
322
326
327
328
323
324
325
331
313
345
346
316
902
903
518
519
463
464
465
894
895
896
897
898
899
332
333
334

Logic Status
Start Inhibits
Limit Status
Local I/O Status
Exception Event1
Exception Event2
Exception Event3
Alarm Status 1
Alarm Status 2
Alarm Status 3
Fault Status 1
Fault Status 2
Fault Status 3
LstFaultStopMode
Heatsink Temp
Drive OL JnctTmp
Drive OL Status
SynchLink Status
SL Error Status
SL Error History
MC Diag Status
MC Diag Done
MC Diag Error 1
MC Diag Error 2
MC Diag Error 3
SL CRC Err Accum
SL CRC Error
SL BOF Err Accum
SL BOF Error
SL CRC Err Limit
SL BOF Err Limit
700L EventStatus*
700L FaultStatus*
700L AlarmStatus*

Test Points

161
162
163
164
329
330
77
78
79
108
109
347
348
130
131
357
358
418
419
178
179
737
738
739
892
893
245
246
247
261
262
270
271
287
288
412
413
466
467
468
473
474
475
476
717
718
719
1145
1146
1147

Logic TP Sel
Logic TP Data
Stop Oper TP Sel
StopOper TP Data
Fault TP Sel
Fault TP Data
Spd Ref TP Sel
Spd Ref TP RPM
Spd Ref TP Data
Spd Reg TP Sel
Spd Reg TP Data
Drive OL TP Sel
Drive OL TP Data
Trq Ref TP Sel
Trq Ref TP Data
Curr Ref TP Sel
Curr Ref TP Data
Brake TP Sel
Brake TP Data
PI TP Sel
PI TP Data
Posit TP Select
PositTP DataDInt
PositTP DataReal
SL Comm TP Sel
SL Comm TP Data
Spd Fdbk TP Sel
Spd Fdbk TP RPM
Spd Fdbk TP Data
Steg&Hiedn TPSel
Steg&Heidn TPDta
Reslvr0 TP Sel
Reslvr0 TP Data
Linear1 TP Sel
Linear1 TP Data
Power EE TP Sel
Power EE TP Data
MC TP1 Select
MC TP1 Value
MC TP1 Bit
MC TP2 Select
MC TP2 Value
MC FaultTPSelect
MC FaultTP Value
PLL TP Select
PLL TP DataDInt
PLL TP DataReal
PPMP TP Select
PPMP TP DataDInt
PPMP TP DataReal

Drive Memory

196
145
147
149
146
148

ParamAccessLevel
ApplicationGroup
FW Functions En
FW FunctionsActl
FW TaskTime Sel
FW TaskTime Actl

Fault/Alm Config

379
374
373
382
381
393
394
376
377
372
371
375
369
365
366
367
391
392
383
384
390
385
386
387
388
389
370
363
364
378
395
396
397
398
399
368

Ext Flt/Alm Cnfg
Motor Stall Cnfg
Motor Stall Time
MC Cmd Lim Cnfg
PreChrg Err Cnfg
BusUndervoltCnfg
VoltFdbkLossCnfg
Inv OL Pend Cnfg
Inv OL Trip Cnfg
Mtr OL Pend Cnfg
Mtr OL Trip Cnfg
Inv OT Pend Cnfg
Brake OL Cnfg
Fdbk LsCnfg Pri
Fdbk LsCnfg Alt
Fdbk LsCnfgPosit
DPI CommLoss Cfg
NetLoss DPI Cnfg
SL CommLoss Data
SL CommLoss Cnfg
SL MultErr Cnfg
Lgx CommLossData
Lgx OutOfRunCnfg
Lgx Timeout Cnfg
Lgx Closed Cnfg
Lgx LinkChngCnfg
HiHp InPhsLs Cfg
HiHp GndFlt Cur
HiHp GndFlt Dly
Interp Flt Cnfg
+Sft OvrTrvlCnfg
-Sft OvrTrvlCnfg
+Hrd OvrTrvlCnfg
-Hrd OvrTrvlCnfg
Position ErrCnfg
Cnv NotLogin Cfg*

Trending

556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585

Trend Control
Trend Status
Trend State
Trend Rate
Trend TrigA DInt
Trend TrigA Real
Trend TrigB DInt
Trend TrigB Real
Trend Trig Data
Trend Trig Bit
Trend PreSamples
Trend Mark DInt
Trend Mark Real
TrendBuffPointer
Trend In1 DInt
Trend In1 Real
Trend Out1 DInt
Trend Out1 Real
Trend In2 DInt
Trend In2 Real
Trend Out2 DInt
Trend Out2 Real
Trend In3 DInt
Trend In3 Real
Trend Out3 DInt
Trend Out3 Real
Trend In4 DInt
Trend In4 Real
Trend Out4 DInt
Trend Out4 Real