1028

Swtch DInt 1 Out

This is the result of the switch. The output is loaded with the selected input based on

Par 1022

[Sel Switch Ctrl],

bit 6 “SW DInt 1 On”. If this parameter does not update, check the setting of

Par 1000

[UserFunct Enable], bit 1

“User Params”.

Default:
Min/Max:

0.0000
-/+2200000000.0000

RO 32-bit

Integer

1029

to

1044

Sel Swtch In00

to

Sel Swtch In15

Set these values for the inputs to the selector switch specified in

Par 1022

[Sel Switch Ctrl]. All inputs are entered

as Real values. You may use the output of the selector switch as either Real or DInt. A conversion is done to create
the DInt value.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

1045

SelSwtch RealOut

This is the result of the selector switch. The output is loaded with the selected input based on

Par 1022

[Sel

Switch Ctrl], bit 0 and bits 1-4. The output is only updated when Par 1022 [Sel Switch Ctrl], bit 0 “SSW DataPass”
is high. If Par 1022 [Sel Switch Ctrl], bit 0 is not high the output will not be updated to the selected input. If this
parameter does not update, check the setting of

Par 1000

[UserFunct Enable], bit 1 “User Params”.

Default:
Min/Max:

0.0000
-/+2200000000.0000

RO Real

1046

SelSwtch DIntOut

This value is the value of

Par 1045

[SelSwtch RealOut] converted to a DInt value. Use this value for point to point

positioning values.

Default:
Min/Max:

0
-/+2147483648

RO 32-bit

Integer

1047

DInt2Real1 In

Input value for a first DInt to Real value conversion.
Note: This parameter name changed from [DInt2Real In] to [DInt2Real1 In] for firmware version 3.001.

Default:
Min/Max:

0
-/+2147483648

Y

RW 32-bit

Integer

1048

DInt2Real1 Scale

Input value to scale the first conversion from DInt to Real. This is a multiplication to the input value after
conversion to a Real value.
Note: This parameter name changed from [DInt2Real Scale] to [DInt2Real1 Scale] for firmware version 3.001.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

1049

DInt2Real1Result

This is the resultant output of the first conversion form a DInt value to a Real value after scaling.
Note: This parameter name changed from [DInt2RealResult] to [DInt2Real1Result] for firmware version 3.001.

Default:
Min/Max:

0.0000
-/+2200000000.0000

RO Real

1050

Real2DInt In

Input value for Real to DInt value conversion.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

1051

Real2DInt Scale

Input value to scale the conversion from Real to DInt. This is a multiplication to the input value after conversion to
a DInt value.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

1052

Real2DInt Result

This is the resultant output of the conversion form a Real value to a DInt value after scaling.

Default:
Min/Max:

0
-/+2147483648

RO 32-bit

Integer

1053

MulDiv 1 Input

Input value to be scaled as need with the Multiplication and Division function. This input will be multiplied by

Par

1054

[MulDiv 1 Mul] and then divided by

Par 1055

[MulDiv 1 Div]. The result will be loaded to

Par 1056

[MulDiv 1

Result].

Equation: (

Par 1053

x

Par 1054

) /

Par 1055

=

Par 1056

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

1054

MulDiv 1 Mul

Set this value as the multiplier to the value of

Par 1053

[MulDiv 1 Input]. The result will be divided by

Par 1055

and loaded into

Par 1056

. See

Par 1053

.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

1055

MulDiv 1 Div

Set this value as the divisor of the result of

Par 1053

x

Par 1054

. The result will be loaded into

Par 1056

. See

Par

1053

.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

1056

MulDiv 1 Result

This is the result output from the Multiplication and Division function. See

Par 1053

.

Equation:

Par 1056

= (

Par 1053

x

Par 1054

) /

Par 1055

Default:
Min/Max:

0.0000
-/+2200000000.0000

RO Real

1057

MulDiv 2 Input

Input value to be scaled as need with the Multiplication and Division function. This input will be multiplied by

Par

1058

[MulDiv 2 Mul] and then divided by

Par 1059

[MulDiv 2 Div]. The result will be loaded to

Par 1060

[MulDiv 2

Result].

Equation: (

Par 1057

x

Par 1058

) /

Par 1059

=

Par 1060

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

1058

MulDiv 2 Mul

Set this value as the multiplier to the value of

Par 1057

[MulDiv 2 Input]. The result will be divided by

Par 1059

and loaded into

Par 1060

. See Par 1057.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

1059

MulDiv 2 Div

Set this value as the divisor of the result of

Par 1057

x

Par 1058

. The result will be loaded into

Par 1060

. See Par

1057.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

1060

MulDiv 2 Result

This is the result output from the Multiplication and Division function. See

Par 1057

.

Equation:

Par 1060

= (

Par 1057

x

Par 1058

) /

Par 1059

Default:
Min/Max:

0.0000
-/+2200000000.0000

RO Real