Par 570, Par 559, Par 569 – Rockwell Automation 20D PowerFlex 700S AC Drives with Phase II Control Programming Manual User Manual

Page 96

Advertising
background image

96

Rockwell Automation Publication 20D-PM001C-EN-P - July 2013

Chapter 2

Programming and Parameters

558

Trend State

Value indicates the state of the Data Trend function.
Value 0 - Wait Enable indicates the trend function is ready and waiting to begin data collection. Setting bit

0 “Enbl Collect” of

Par 556

[Trend Control] will cause data collection to begin. In this state,

Par 569

[TrendBuffPointer] and the Trend Output Parameters are active.

Value 1 - First Scan indicates the Trend function is executing the first pass through the trend sample buffer.

This takes 512 ms. (0.5 ms x 1024 samples). When it enters this state, the Trend function clears bit 1
“Triggered” and 2 “Complete” bits of

Par 557

[Trend Status]. While in this state, the Trend function

refreshes the data. Also while in this state, the function forces the Trend Output parameters to zero. When
done, it enters the Pre-trigger state.

Value 2 - Pre-trigger indicates the Trend function is sampling the trend inputs and storing them in

memory, at a rate determined by

Par 559

[Trend Rate]. Sampling continues until either the trend trigger

event occurs or bit 0 “Enbl Collect” of

Par 556

[Trend Control] is cleared. While in this state, the Trend

function forces the Trend Output parameters to zero. If the trigger event occurs, the function sets bit 1
“Triggered” of

Par 557

[Trend Status] and enters the Post-trigger state. If bit 0 “Enbl Collect” of Parameter

556 [Trend Control] is cleared, the function sets bit 2 “Complete” of Par 557 [Trend Status] and returns to
the Wait Enable state.

Value 3 - Post-trigger indicates the Trend function is continuing to sample and save the trend inputs until

the buffer is full. While in this state, the function forces the Trend Output parameters to zero value. When
the buffer is full, the function sets bit 2 “Complete” of

Par 557

[Trend Status] and enters the Wait Disable

state.

Value 4 - Wait Disable indicates the Trend function is complete and waiting for bit 0 “Enbl Collect” of

Par

556

[Trend Control] to be cleared. When this is done, the trend function returns to the Wait Enable state.

While in the Wait Disable state,

Par 569

[TrendBuffPointer] and the Trend Output Parameters are active.

Default:

Options:

0 =

0 =
1 =
2 =
3 =
4 =

“Wait Enable”

“Wait Enable”
“First Scan”
“Pre-trigger”
“Post-trigger”
“Wait Disable”

559

Trend Rate

Sets the sample time for both trend input and output updates.

Default:
Min/Max:
Units:

0.5000
0.5000/1000.0000
ms

Y

RW Real

560

Trend TrigA DInt

Provides the integer input for the A trigger function. This integer is converted to a real number and summed
with

Par 561

[Trend TrigA Real]. The result is compared with the Trigger B sum. If the A sum exceeds the B sum,

then a trend trigger will occur.

Default:
Min/Max:

0
-/+2147483648

Y

RW 32-bit

Integer

561

Trend TrigA Real

Provides the real input for the A trigger function. This real number is summed with

Par 560

[Trend TrigA Int].

The result is compared with the Trigger B sum. If the A sum exceeds the B sum, then a trend trigger will occur.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

562

Trend TrigB DInt

Provides the integer input for the B trigger function. This integer is converted to a real number and summed
with

Par 563

[Trend TrigB Real]. The result is compared with the Trigger A sum. If the A sum exceeds the B sum,

then a trend trigger will occur.

Default:
Min/Max:

0
-/+2147483648

Y

RW 32-bit

Integer

563

Trend TrigB Real

Provides the real input for the B trigger function. This real number is summed with

Par 562

[Trend TrigB Int].

The result is compared with the Trigger A sum. If the A sum exceeds the B sum, then a trend trigger will occur.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

564

Trend Trig Data

This is the logic input for the Trend Trigger Function. A trigger will occur on the rise of the specified bit in this
word. The bit will be specified by

Par 565

[Trend Trig Bit].

Default:
Min:
Max:

00000000000000000000000000000000
00000000000000000000000000000000
11111111111111111111111111111111

Y

RW 32-bit

Boolean

565

Trend Trig Bit

Specifies the bit in

Par 564

[Trend Trig Data] that will cause a Trend Trigger to occur. Positive numbers specify

rising edges and negative numbers specify falling edges.

Default:
Min/Max:

0
-32/31

Y

RW 16-bit

Integer

566

Trend PreSamples

Specifies the number pre-trigger samples in the trend buffer. Pre-trigger samples are the samples that occur
before the trigger and remain in the buffer. The remainder of the trend buffer will contain post-trigger
samples.

Default:
Min/Max:

511
0/1022

Y

RW 16-bit

Integer

567

Trend Mark DInt

Marks the start of data for trend buffers that are using integer data. The Trend Marker can be used to provide a
scope trigger signal for the Auto Output function.

Default:
Min/Max:

0
-/+2147483648

Y

RW 32-bit

Integer

568

Trend Mark Real

Marks the start of data for trend buffers that are using real data. The Trend Marker can be used to provide a
scope trigger signal for the Auto Output function.

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

569

TrendBuffPointer

Selects the trend buffer element to be displayed in the Trend Output Parameters when the trend function is
inactive (not collecting data samples). A zero value points to the element that corresponds to the trigger event.
Negative values point to pre-trigger data. Positive values point to post-trigger data. When the Auto Output
function is running, this parameter will automatically sequence through it's full range, at a rate set by

Par 559

[Trend Rate].

Default:
Min/Max:

0
-/+1023

Y

RW 16-bit

Integer

570

Trend In1 DInt

Provides integer input to the Trend 1. The Trending function samples this parameter for Trend Buffer 1, if bit 1
“In 1 Real” is cleared.

Default:
Min/Max:

0
-/+2147483648

Y

RW 32-bit

Integer

No.

Name
Description

Values

Link

able

Re

ad

-Write

Da

ta

T

yp

e

Val 2

Pre-Trigger

Val 0

Wait Enable

Val 1

First Scan

Val 3

Post-Trigger

Val 4

Wait Disable

Enbl Collect

Enbl Collect

Done

Trigger Event

Buffer Full

Enbl Collect

Advertising