1073

Compare 2A

Sets input A for the Compare 2. The compare functions allow the user to compare two values. The results of the
compare are displayed in

Par 1062

[Logic/Cmpr State].

Available functions are ( A </= B , A >/= B ).

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

1074

Compare 2B

Sets input B for the Compare 2. The compare functions allow the user to compare two values. The results of the
compare are displayed in

Par 1062

[Logic/Cmpr State].

Available functions are ( A </= B , A >/= B ).

Default:
Min/Max:

0.0000
-/+2200000000.0000

Y

RW Real

1086

MOP Control

Motor Operated Potentiometer (MOP) control and configuration.
• Bit 0 “Increase”, if set, increments the MOP level (output) from

Par 1087

[MOP Rate] to

Par 1088

[MOP High Limit].

• Bit 1 “Decrease”, if set, decrements the MOP level (output) from Par 1087 [MOP Rate] to

Par 1089

[MOP Low Limit].

• Bit 2 “Reset”, if set, resets the MOP level (output) to zero and bit 0 “Increment” and bit 1 “Decrease” are inhibited.
• Bit 3 “Reset @ Stop”, if set, resets the MOP level (output) to zero when stop is set.
• Bit 4 “Reset @ PwrLs”, if set, resets the MOP level (output) to zero when power is lost.
Note: If either bit 3 or bit 4 is not set, the MOP level (output) will be saved until bit 2 “Reset” is set.

1087

MOP Rate

Sets the rate of change (increment or decrement) for the MOP. The setting 0.1/sec will equate to an increment or
decrement of 0.1 for every second active. If this is used for the speed reference, that equals 10% of base speed
every second for a total of 10 seconds to reach base speed reference.

Default:
Min/Max:
Units:

0.1000 s
0.0000/2200000000.0000
s

Y

RW Real

1088

MOP High Limit

Sets the upper limit for the MOP output. The MOP cannot be incremented above this level.

Default:
Min/Max:
Units:

1.0000 s
0.0000/2200000000.0000
s

Y

RW Real

1089

MOP Low Limit

Sets the lower limit for the MOP output. The MOP cannot be decremented below this level.

Default:
Min/Max:
Units:

-1.0000 s
-2200000000.0000/0.0000
s

Y

RW Real

1090

MOP Level Real

Actual output value of the MOP as a real number. This value is also found in the speed reference selection. A value
of 1.0 equals base motor speed.

Default:
Min/Max:
Units:

0.0000
-/+2200000000.0000
s

RO Real

1091

MOP Scale Dint

Set this value for scaling of the Dint MOP output. The MOP is calculated and controlled as a Real value MOP. Use
this scaler to adjust for an integer value. Use this parameter to scale the conversion from

Par 1090

[MOP Level

Real] to

Par 1092

[MOP Level Dint].

Default:
Min/Max:

1.0000
-/+2200000000.0000

Y

RW Real

1092

MOP Level DInt

Actual output value of the MOP as a DInt number. This value is scaled by

Par 1091

[MOP Scale DInt].

Default:
Min/Max:

0.0000
-/+2147483648

RO 32-bit

Integer

1093

1094

1095

Anlg In1LossCnfg

Anlg In2LossCnfg

Anlg In3LossCnfg

Selects drive action when an analog input signal loss is detected. Signal loss is defined as an analog signal less
than 1 V or 2 mA. The signal loss event ends and normal operation resumes when the input signal is greater than
or equal to 1.5 V or 3 mA.
Note: This parameter was added for firmware version 3.001.

Default:

Options:

0 =

0 =
1 =
2 =
3 =

“Disabled”

“Disabled”

4 = “Set Input Hi”

“Fault”

5 = “Goto Preset1”

“Hold Input”

6 = “Hold OutFreq”

“Set Input Lo”

1096

AddSub 1 Input

Input value to be added to and/or subtracted from as need with the Add and Subtract function. This input will be
added with

Par 1097

[AddSub 1 Add]. The result will be subtracted from by the value in

Par 1098

[AddSub 1

Subtrct]. The result of the operation is loaded to

Par 1099

[AddSub 1 Result].

Equation: Par (1096 + Par 1097) - Par 1098 = Par 1099

Note: This parameter was added for firmware version 3.001.

Default:
Min/Max:

1.0000
-/+2200000000.0000

Y

RW Real

1097

AddSub 1 Add

This value is added to the value of

Par 1096

[AddSub 1 Input]. The result will be subtracted from by

Par 1098

and

loaded into

Par 1099

. See

Par 1096

.

Note: This parameter was added for firmware version 3.001.

Default:
Min/Max:

1.0000
-/+2200000000.0000

Y

RW Real

1098

AddSub 1 Subtrct

This value is subtracted from the result of

Par 1096

+

Par 1097

. The result will be loaded into

Par 1099

. See Par

1096.
Note: This parameter was added for firmware version 3.001.

Default:
Min/Max:

1.0000
-/+2200000000.0000

Y

RW Real

No.

Name
Description

Values

Link

able

Re

ad

-Write

Da

ta

T

yp

e

Options

Re

se

t @

PwrLs

Re

se

t @

St

op

Re

se

t

Dec

rea

se

Inc

re

as

e

Default

0

0

0

0

0

Bit

4

3

2

1

0