Par 532, D by, Par 531 – Rockwell Automation 20D PowerFlex 700S AC Drives with Phase II Control Programming Manual User Manual

Page 93: Maximum v

Advertising
background image

Rockwell Automation Publication 20D-PM001C-EN-P - July 2013

93

Programming and Parameters

Chapter 2

527

Start/Acc Boost

Sets the voltage boost level for starting and acceleration when “V/Hz” mode is selected.
Note: This parameter was added for firmware version 2.003.

Default:
Min/Max:
Units:

50.0
0.0/1150.0
VAC

RW 16-bit

Integer

528

Run Boost

Sets the boost level for steady state or deceleration when “V/Hz” mode is selected.
Note: This parameter was added for firmware version 2.003.

Default:
Min/Max:
Units:

50.0
0.0/1150.0
VAC

RW 16-bit

Integer

529

Break Voltage

Sets the voltage the drive will output at

Par 530

[Break Frequency].

Note: This parameter was added for firmware version 2.003.

Default:
Min/Max:
Units:

1150.0
0.0/6900.0
VAC

RW 16-bit

Integer

530

Break Frequency

Sets the frequency the drive will output at

Par 529

[Break Voltage].

Note: This parameter was added for firmware version 2.003.

Default:
Min/Max:
Units:

150.0
0.0/400.0
Hz

RW 16-bit

Integer

531

Maximum Voltage

Sets the highest voltage the drive will output.
Note: This parameter was added for firmware version 2.003.

Default:
Min/Max:
Units:

460.0
60.0/690.0
VAC

RW 16-bit

Integer

532

Maximum Freq

Sets the highest frequency the drive will output. This parameter is a function of

Par 3

[Motor NP Hertz].

Note: This parameter was added for firmware version 2.003.

Default:
Min/Max:
Units:

(

Par 3

[Motor NP Hertz] x 2) + 10Hz

Par 3 [Motor NP Hertz] + 10 Hz/420.0
Hz

RW 16-bit

Integer

533

SlewRateTimeLimt

Defines the time limit in seconds during which torque producing voltage (Vqs) regulator output variations are
limited by each slew rate at the transition where the Vqs regulator turns on. The same time limit is applied at
the transition to the slip regulator when the slip regulator turns on. A value of zero disables the slew rate
function on both the Vqs regulator output and the slip regulator output. Par 553 defines the slew rate for the
slip regulator and

Par 586

[IdsCmd Slew Rate] defines the slew rate for the Vqs regulator.

Notes: This parameter was added for firmware version 3.001. This parameter was renamed from “Flux Gain
Adjust” to “SlewRateTimeLimit”, the default value was changed to “10.0” and the minimum value was
changed to “0.0” for firmware version 4.001.

Default:
Min/Max:

0.0
0.0/1126.0

RW 16-bit

Integer

534

Nth CompOff Freq

The Nth compensation current amplitude is constant (defined by

Par 595

[Nth Amplitude]) up to this

frequency, then linearly reduced to zero at the frequency of Par 534 + 6.25%.
Note: This parameter was added for firmware version 5.002.

Default:
Min/Max:
Scaling:

819
0/32767
4096/

Par 3

[Motor NP Hertz]

RW 16-bit

Integer

535

Mth CompOff Freq

The Mth compensation current amplitude is constant (defined by

Par 598

[Mth Amplitude]) up to this

frequency, then linearly reduced to zero at the frequency of Par 535 + 6.25%.
Note: This parameter was added for firmware version 5.002.

Default:
Min/Max:
Scaling:

819
0/32767
4096/

Par 3

[Motor NP Hertz]

RW 16-bit

Integer

537

SrLssAngleStblty

Adjusts the electrical angle to maintain stable motor operation. An increase in the value increases the angle
adjustment.

Default:
Min/Max:

51.0
0.0/32767.0

RW 16-bit

Integer

538

SrLss VoltStblty

Adjusts the voltage to maintain stable motor operation. An increase in the value increases the output voltage
adjustment.

Default:
Min/Max:

93.0
0.0/32767.0

RW 16-bit

Integer

539

SrLss StbltyFilt

The coefficient is used to adjust the bandwidth of a low pass filter. The smaller the value of the coefficient, the
lower the bandwidth of the filter.

Default:
Min/Max:

3250.0
0.0/32767.0

RW 16-bit

Integer

540

V/Hz Status

Indicates the limit status of the V/Hz Control Operation.
Note: This parameter was added form firmware version 2.003.

541

SrLss Angl Comp

Not currently used.
Note: This parameter was added for future use - not active for use with firmware version 2.003 and above.

Default:
Min/Max:

0.0
+/- 16384

RW 16-bit

Integer

542

SrLss Volt Comp

Not currently used.
Note: This parameter was added for future use - not active for use with firmware version 2.003 and above.

Default:
Min/Max:
Units:

100.0
+/- 1000.0
V

RW 16-bit

Integer

544

External DB Res

Sets the resistance value of an external dynamic braking resistor. This value is used to determine the power
applied to the resistor and thus calculate its temperature.
Note: This parameter was added for firmware version 4.001.

Default:
Min/Max:
Units:

49.0
0.1/500.0
Ohm

RW Real

No.

Name
Description

Values

Link

able

Re

ad

-Write

Da

ta

T

yp

e

A

A

A

A

A

A

A

A

A

A

A

A

Options

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Bus

V

ol

t Li

m

Cu

rr

en

t L

im

Default

x

x

x

x

x

x

x

x

x

x

x

x

x

x

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

A

A

Advertising