Preferences menu, View and edit parameters, Lcd him – Rockwell Automation 20D PowerFlex 700S AC Drives with Phase II Control Programming Manual User Manual

Page 158: Numeric keypad shortcut, Lcd him numeric keypad shortcut, R to view and edit parameters

Advertising
background image

158

Rockwell Automation Publication 20D-PM001C-EN-P - July 2013

Appendix A

Human Interface Module Overview

Preferences Menu

The HIM and drive have features that you can customize.

The PowerFlex 700S drive is initially set to Basic Parameter View. To view all
parameters, set parameter 196 [ParamAccessLvl] to option 1 “Advanced”.
Parameter 196 is not affected by the Reset to Defaults function.

View and Edit Parameters

LCD HIM

Numeric Keypad Shortcut

If using a HIM with a numeric keypad, press the ALT key and the +/– key to
access the parameter by typing its number.

Option

Description

Drive Identity

Add text to identify the drive.

Change Password

Enable/disable or modify the password.

User Dspy Lines

Select the display, parameter, scale and text for the User Display. The User Display is two lines of
user-defined data that appears when the HIM is not being used for programming.

User Dspy Time

Set the wait time for the User Display or enable/disable it.

User Dspy Video

Select Reverse or Normal video for the Frequency and User Display lines.

Reset User Dspy

Return all the options for the User Display to factory default values.

Steps:

Key(s):

Example Displays”

1. In the Main Menu, press the Up Arrow or Down Arrow to scroll

to “Parameter.”

2. Press Enter. “FGP File” appears on the top line and the first

three files appear below it.

3. Press the Up Arrow or Down Arrow to scroll through the files.

4. Press Enter to select a file. The groups in the file are displayed

under it.

5. Repeat steps 3 and 4 to select a group and then a parameter.

The parameter value screen will appear.

6. Press Enter to edit the parameter.

7. Press the Up Arrow or Down Arrow to change the value. If

desired, press Sel to move from digit to digit, letter to letter,
or bit to bit. The digit or bit that you can change will be
highlighted.

8. Press Enter to save the value. If you want to cancel a change,

press Esc.

9. Press the Up Arrow or Down Arrow to scroll through the

parameters in the group, or press Esc to return to the group
list.

Sel

Esc

or

or

or

or

F

GP: File

Monitor

Motor Control

Dynamic Control

FGP:

Par 2

Motor NP FLA

1.000

Amps

[ALT][VIEW] -> Limits

FGP:

Par 2

Motor NP FLA

1.500 Amps

[ALT][VIEW] -> Limits

F

G

P: Group

Motor Data

Monitoring
Drive Config

FG

P

: Parameter

Motor NP Volts

Motor NP FLA

Motor NP Hertz

Advertising