91

Programming and Parameters

Chapter 2

514 Test

Mode

Config

Configures the Motor Control (MC) test mode.
Note: This parameter was changed to non-linkable for firmware version 3.001.

515

FVC Tune Config

Configures FOC tuning mode.
Bit 1 “FluxCurrTune” when set, the value in

Par 488

[Flux Current] is used as the flux current at the beginning of the magnetic inductance test. When this bit is not set (default), an automatically

calculated (preset) flux current is used as the flux current at the beginning of the magnetic inductance test.

Bit 2 “NoTimeLimit” when set, the time limit fault detection during the magnetizing inductance test is disabled.
Note: Bits 1 and 2 were added for firmware version 4.001.

516

FVC2 Tune Config

Configures FOC 2 tuning mode.

No.

Name
Description

Values

Link

able

Re

ad

-Write

Da

ta

T

yp

e

ATTENTION: Do not modify this parameter. Motor/Drive instabilities and damage may result.

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

flW

av

e C

omp

Bus

Gai

n C

om

p

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Default

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

1

1

x

x

x

x

x

x

x

x

Bit

31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

ATTENTION: Do not modify this parameter. Motor/Drive instabilities and damage may result.

Options

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

No

Ro

ta

te

Tu

ne

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

Res

er

ve

d

No

Tim

eL

imi

t

Fl

ux

Cu

rr

Tu

ne

Res

er

ve

d

Default

x

x

x

x

x

x

0

x

x

x

x

x

x

0

0

x

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

ATTENTION: Do not modify this parameter. Motor/Drive instabilities and damage may result.

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

N

oRo

tate

Tu

ne

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Default

x

x

x

x

x

x

0

x

x

x

x

x

x

x

x

x

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

Advertising