Stop Dwell Time

Sets an adjustable delay time between detecting zero speed and disabling the
speed and torque regulators, when responding to a stop command.

Figure 7 - Drive Operation When Par 154 [Stop Dwell Time] Equals Zero

Figure 8 - Drive Operation When Par 154 [Stop Dwell Time] is Greater Than Zero

IMPORTANT

Consult industry and local codes when setting the value of this parameter.

P 160 [Zero Speed Lim]

S

peed

Dr

iv

e Receiv

es

S

top Comm

and

0

Time

Dr

iv

e Detect

s Zero

S

peed

and T

urn

s Off Reg

ul

ator

s

When Par 154 [Stop Dwell Time] equals zero, the drive turns off
the velocity and torque regulators when it detects zero speed.

P 160 [Zero Speed Lim]

S

peed

Dr

iv

e Receiv

es

S

top Comm

and

0

Time

Dr

iv

e Detect

s Zero

S

peed

Dr

iv

e T

urn

s Off Reg

ul

ator

s

P 154 [Stop Dwell Time]

When Par 154 [Stop Dwell Time] is greater than zero, the drive delays
turning off the velocity and torque regulators for the amount of time
specified in Par 154.