Par 1155 – Rockwell Automation 20D PowerFlex 700S AC Drives with Phase II Control Programming Manual User Manual

Page 129

Advertising
background image

Rockwell Automation Publication 20D-PM001C-EN-P - July 2013

129

Programming and Parameters

Chapter 2

1150

DInt2Real2 In

Input value for a second DInt to Real value conversion.
Note: This parameter was added for firmware version 3.001.

Default:
Min/Max:

0
-/+2147483648.0

Y

RW 32-bit

Integer

1151

DInt2Real2 Scale

Input value to scale the second conversion from DInt to Real. This is a multiplication to the input value after
conversion to a Real value.
Note: This parameter was added for firmware version 3.001.

Default:
Min/Max:

0.0
-/+2200000000.0

Y

RW Real

1152

DInt2Real2Result

This is the resultant output of the second conversion form a DInt value to a Real value after scaling.
Note: This parameter was added for firmware version 3.001.

Default:
Min/Max:

0.0
-/+2200000000.0

RO Real

1155

Heidn VM Pos Ref

Virtual Master position reference for the Heidenhain option card. This value is used by the Virtual Master function
as a position reference. This parameter can be linked to a position reference source, such as

Par 1160

[VirtEncPositFast].
Note: This parameter was added for firmware version 4.001.

Default:
Min/Max:

0.0
-/+2147483648.0

Y

RW 32-bit

Integer

1156

Heidn VM Enc PPR

Virtual Master Encoder Pulse per Revolution (PPR). This value defines the encoder PPR for the Virtual Master
function. The Heidenhain option card produces the encoder pulse according to this PPR value, which is limited to
1024 or 2048 encoder lines.
Note: This parameter was added for firmware version 4.001.

Default:
Min/Max:
Units:

1024
1024 and 2048 only
PPR

RW 32-bit

Integer

1160

VirtEncPositFast

Virtual Encoder position output in Task 1. One of three outputs from the Virtual Encoder function. This value is the
encoder position reference output for Task1 (fast rate).

Par 62

[Virt Encdr Posit] and

Par 63

[Virt Encdr Dlyed] are

the encoder position output in Task 2. For the Virtual Master Encoder function, you must use Par 1160
[VirEncPosiFast] as the position reference updated in Task 1.
Note: This parameter was added for firmware version 4.001.

Default:
Min/Max:

0.0
-/+2147483648.0

RO 32-bit

Integer

1161

EGR Config

Configuration for the Electrical Gear Ratio (EGR) user function. Setting bit 7 “EGR” of

Par 1000

[UserFunct Enable] enables the EGR user function. The combination of bit 0 “Output Sel 0” and bit 1

“Output Sel 1” determines the output of the EGR user function as follows:

Note: This parameter was added for firmware version 4.001.

1162

EGR Mul

Multiplier (numerator) of the EGR user function position input.
(

Par 1164

[EGR Pos Input] x Par 1162 [EGR Mul]) /

Par 1163

[EGR Div] =

Par 1165

[EGR Pos Output]

Note: This parameter was added for firmware version 4.001.

Default:
Min/Max:

1.0
-/+2000000.0

Y

RW 32-bit

Integer

1163

EGR Div

Divisor (denominator) of the EGR user function position input.
(

Par 1164

[EGR Pos Input] x

Par 1162

[EGR Mul]) / Par 1163 [EGR Div] =

Par 1165

[EGR Pos Output]

Note: This parameter was added for firmware version 4.001.

Default:
Min/Max:

1.0
+1.0/+2000000.0

Y

RW 32-bit

Integer

1164

EGR Pos Input

Position reference input to the Electrical Gear Ratio user function. This parameter can be linked to a position
reference source, such as

Par 1160

[VirtEncPositFast].

Note: This parameter was added for firmware version 4.001.

Default:
Min/Max:

0.0
-/+2147483648.0

Y

RW 32-bit

Integer

1165

EGR Pos Output

Position reference output from the Electrical Gear Ratio user function. This parameter can be linked to a position
reference sink, such as

Par 1155

[Heidn VM Pos Ref].

Note: This parameter was added for firmware version 4.001.

Default:
Min/Max:

0.0
-/+2147483648.0

RO 32-bit

Integer

1166

EGR Pos Preset

A preset value for the Electrical Gear Ratio user function. This value is set to the value in

Par 1165

[EGR Pos

Output] when bits 0 “Output Sel 0” and 1 “Output Sel 1” of

Par 1161

[EGR Config] are set.

Note: This parameter was added for firmware version 4.001.

Default:
Min/Max:

0.0
-/+2147483648.0

Y

RW 32-bit

Integer

1170

MC Generic 1

For Future Use.
Note: This parameter was added for firmware version 4.001.

Default:
Min/Max:

0
+/-32767

RW 16-bit

Integer

No.

Name
Description

Values

Link

able

Re

ad

-Write

Da

ta

T

yp

e

Bit 1

Bit 0

Description

0

0

Par 1165

[EGR Pos Output] is set to zero

0

1

Par 1165 [EGR Pos Output] is active

1

0

Par 1165 [EGR Pos Output] is set to the value of

Par 1164

[EGR Pos Input]

1

1

Par 1165 [EGR Pos Output] is set to the value of

Par 1166

[EGR Pos preset]

Options

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Re

se

rv

ed

Ou

tp

ut

S

el

1

Ou

tp

ut

S

el

0

Default

x

x

x

x

x

x

x

x

x

x

x

x

x

x

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

Advertising