Po s ition control - interp /direct, T as k 2 ), Pos_control_inter_dir.eps – Rockwell Automation 20D PowerFlex 700S AC Drives with Phase II Control Programming Manual User Manual

Page 186

Advertising
background image

186

Rockwell Automation Publication 20D-PM001C-EN-P - July 2013

Appendix C

Control Block Diagrams

Interpol

a

tor

x

x

x

748

0

1

2

749

743

742

Ge

a

r R

a

t

[ N

]

[ D

]

745

746

Po

s

itRef EGR M

u

l

Po

s

itRef EGR Div

+

R

a

te Lim

753

754

755

LP

ass

Filter

756

744

747

762

764

P G

a

in

kp

768

I G

a

in

ki

s

770

Limit

772

773

774

+

Ge

a

r R

a

t

[ N

]

[ D

]

766

767

Link

763

765

Droop

771

Inv

&

Limit

0

318

775

776

Po

s

ition Act

ua

l

Po

s

it Actl Lo

a

d

Po

s

itReg Integ

Po

s

itReg Droop

Po

s

itReg P G

a

in

XReg Integ O

u

t

Po

s

ition

S

ta

tus

XReg Integ LoLim

XReg Integ HiLim

Po

s

ition

S

ta

tus

Co

a

rs

ePo

s

it Trgt

Po

s

ition Control

(Interp Rev

)

X

s

ync

S

ta

tus

(S

ync P

u

ls

e)

Interp Po

s

ition

A

u

x Po

s

it Ref

Po

s

it Off

s

et 1

Po

s

it Off

s

et 2

Po

s

it Off

s

et

S

pd

X Off

s

t

S

pdFilt

Po

s

ition Control

(X Off

s

et Pol

)

Po

s

ition Control

(XOff ReRef

)

Po

s

itRef EGR O

u

t

Po

s

ition Cmmd

Po

s

ition Control

-

Interp

/Direct

(T

as

k 2

)

Po

s

it Lo

a

d Fd

b

k

Po

s

it FB EGR M

u

l

Po

s

it FB EGR Div

Po

s

ition Control

(Integ En

)

Po

s

ition Control

(Integ Hold

)

XReg

S

pd LoLim

XReg

S

pd HiLim

*

*

*

Po

s

it Ref

S

el

Po

s

it

S

pd O

u

tp

u

t

769

Po

s

ition Error

from

S

peed

/Po

s

it

Fd

b

k [

9

H

3

]

to

S

peed Control

-

Reg

u

la

tor [

5

A

2

]

S

ee Point

-to

-Point

Po

s

ition Control

Di

a

gr

a

m p

a

ge 8

*

&

740

01

157

03

O

u

tp

u

t En

ab

le

Logic Ctrl

S

ta

te

(p

o

s

ition en

ab

le

)

Logic Ctrl

S

ta

te

(p

o

s

ition en

ab

le

)

1

2

3

4

5

6

B

A

D

C

F

E

H

G

I

Notch

II

R

796

Po

s

it Ge

a

r R

a

tio

741

2

741

3

1

[1

5

H

5

]

740

02

740

03

157

03

C

a

lib

Con

s

t

C

a

lib

Con

s

t

741

00

741

01

779

778

[1

5

H

5

]

0

X Notch Atten

u

X Notch FiltFreq

740

04

740

05

Motor

S

peed

Ge

a

r O

u

tp

u

t

S

pd

()

750

740

13

Co

a

rs

e

S

pd Trgt

693

00

786

00

700

00

Motn Po

s

it

S

ync

p

786 or

p

700 m

us

t

b

e linked to p

693

for

proper Interpol

a

tor oper

a

tion

752

751

Interp AccelR

a

te

Interp

S

peed

Interp

S

yncInp

u

t

741

05

Po

s

ition

S

ta

tus

(XOffReRef Act

)

+

+

+

-

+

-

+

-

Po

s

ition Fd

b

k

*

Po

s

ition Control

Xzero Pre

s

et

740

08

On the ri

s

ing edge

(a

ctiv

a

tion

) of p

741

b

it 7

[15

H

5

]

the

following

b

it

ass

ignment

s

occ

u

r:

1

) If p

740

b

it 8

is

s

et

, then

p

763

,

p

765

,

p

744

,

a

nd p

747

get

lo

a

ded with

[Po

s

ition Fd

b

k (

p

762

)

-

A

bs

Po

s

it Off

s

et (

p

757

)].

2

) If p

740

b

it 8

is

re

s

et

, then

p

763

, p

765

, p

744

,

a

nd p

747

get

lo

a

ded with the reference v

a

lu

e

(prior to reference deriv

a

tive

fu

nction in coordin

a

te [

D

2

]).

757

A

bs

Po

s

it Off

s

et

Thi

s

point i

s

a

delt

a

ch

a

nge

.

When the po

s

ition loop i

s

fir

s

t

en

ab

led the po

s

ition comm

a

nd

a

nd feed

ba

ck delt

a

a

re zero

.

Δ

Δ

Δ

Δ

Δ

pos_control_inter_dir.eps