Fault/Alarm Descriptions

Table 6 - Fault/Alarm Descriptions, Actions and Configuration Parameters

No.

Name

Type

(1)

Description

Action

1

Abs Ovespd Det

1

The motor speed has exceeded the limits set in

Par 75

[Rev Speed Limit],

Par

76

[Fwd Speed Limit] and

Par 335

[Abs OverSpd Lim].

Check to see if the encoder feedback polarity is

correct.

Check to see if the drive is in torque mode (selected in

Par 110

[Speed/TorqueMode] value 2 “Torque Ref”).

If the drive is in torque mode, verify that there is a
load present.

Verify the min/max settings in Par 75 [Rev Speed

Lim] and Par 76 [Fwd Speed Lim].

Check to see if the load is overhauling. If it is

overhauling, turn the bus regulator off using

Par 414

[Brake/Bus Cnfg] bit 2 “BusRef High”.

2

Vref Decel Fail

1

The value of

Par 301

[Motor Spd Ref] has failed to decrease during a ramp to

zero speed stop.

This could possibly be due to a speed trim from

Par 21

[Speed Trim 1],

Par 22

[Speed Trim 2] or

Par 23

[Speed

Trim 3].

3

Encoder 0 Loss

2

One of the following has occurred on encoder 0:

missing encoder (broken wire)
quadrature error
phase loss

Reconnect or replace the encoder.
Configured with

Par 365

[Fdbk LsCnfg Pri],

Par 366

[Fdbk

LsCnfg Alt], and

Par 367

[Fdbk LsCnfgPosit].

4

Encoder 1 Loss

2

One of the following has occurred on encoder 1:

missing encoder (broken wire)
quadrature error
phase loss

Reconnect or replace the encoder.
Configured with

Par 365

[Fdbk LsCnfg Pri],

Par 366

[Fdbk

LsCnfg Alt], and

Par 367

[Fdbk LsCnfgPosit].

5

Opt Port 0 Loss

2

A fault on port 0 of the Hi-Resolution Encoder feedback option card, MDI
option card, Heidenhain option card, or Resolver feedback option card has
occurred.

Par 260

[Stegmann0 Status] displays the fault status for port 0 of the Hi-

Resolution Encoder feedback option card.

Par 264

[Heidenhain0 Stat] displays the fault status for port 0 of the

Heidenhain feedback option card.

Par 269

[Resolver0 Status] displays the fault status for port 0 of the

Resolver feedback option card.

Reconnect or replace the encoder

Reconnect the option feedback card
Configured with

Par 365

[Fdbk LsCnfg Pri],

Par 366

[Fdbk

LsCnfg Alt], and

Par 367

[Fdbk LsCnfgPosit].

6

Opt Port 1 Loss

2

The Linear sensor portion of the MDI feedback option card has detected a fault
condition.

Par 286

[Linear1 Status] displays the fault status for linear portion of the

MDI feedback option card.

Reconnect or replace the encoder.

Reconnect the feedback option card.
Configured with

Par 365

[Fdbk LsCnfg Pri],

Par 366

[Fdbk

LsCnfg Alt], and

Par 367

[Fdbk LsCnfgPosit].

7

Params Defaulted

1

All parameters are reset to default by user.

(Informational Only)

8

SLink HW Fail

1

A fault has occurred while loading the SynchLink firmware into FPGA on the
Main Control board at power up.

Replace the Main Control board.

9

SLink Comm Fail

2

A SynchLink communication fault has occurred.

Par 902

[SL Error Status] displays SynchLink errors.

Verify the SynchLink configuration in:

Par 904

[SL Node Cnfg]

Par 905

[SL Rx CommFormat], and

Par 910

[SL Tx CommFormat]

Reconnect SynchLink communication fibers.
Configured with

Par 384

[SL CommLoss Cnfg].

10

Drive Power Loss

1

One of the following has occurred:
DC Bus voltage has fallen below the minimum value.

Par 306

[DC Bus Voltage] displays bus voltage.

Par 330

[Fault TP Data] displays the minimum value when

Par 329

[Fault TP

l] is set to five.

The drive must first complete precharge before this check is made.

Verify AC line power.

11

Motor OLoad Trip

2

A motor overload trip has occurred.

Par 308

[Output Current] is squared, scaled

and integrated over time. When this integrated value exceeds 1.0, this
exception event occurs.

The integrator's output can be viewed in

Par 330

[Fault TP Data] when

Par 329

[Fault TP l] is set to 13 “Mtr OL Outpt”. The overload integration rate is affected
by

Par 336

[Motor OL Factor],

Par 337

[Mtr I2T Curr Min],

Par 338

[Mtr I2T Spd

Min] and

Par 339

[Mtr I2T Calibrat].

Reduce mechanical load

Enter correct motor nameplate full load amps

Par 2

[Motor NP FLA]

Configured with

Par 371

[Mtr OL Trip Cnfg]