Rockwell Automation 20D PowerFlex 700S AC Drives with Phase II Control Programming Manual User Manual

Page 20

Advertising
background image

20

Rockwell Automation Publication 20D-PM001C-EN-P - July 2013

Chapter 2

Programming and Parameters

Table 2 - Table Explanation

1

2

3

No.

Name
Description

Values

Link

able

Re

ad-

W

ri

te

Da

ta

T

ype

4

Motor NP RPM

Set to the motor nameplate rated rpm.

Default:
Min/Max:
Units:
Scale:

Calculated
1/30000
rpm
Par 4 [Motor NP RPM] = 1.0 P.U.

RW 16-bit

Integer

110

Speed/TorqueMode

Selects the source for the drive torque reference.

Default:

Options:

1 =

0 =
1 =
2 =
3 =

“Speed Reg”

“Zero Torque”

4 = “Max Spd/Torq”

“Speed Reg”

5 = “Sum Spd/Torq”

“Torque Ref”

6 = “AbsMn Spd/Tq”

“Min Spd/Torq”

151

Logic Command

The controller-drive interface (as defined by the Controller Communication Format) sets bits to enable and disable various functions and algorithms. Bits that are changed here are reflected in

Par

152

[Applied LogicCmd].

Note: Bits 4 through 9 in Logic Command are NOT recalled from Control EEprom. They will be cleared upon drive powerup or following an EEprom recall operation.

Options

PI T

rim Rst

PI T

rim Hold

Po

si

tio

n E

n

PI T

rim E

n

Fr

ic

t C

om

p

Ine

rti

a C

om

p

Ex

t F

lt/A

lm

Re

se

rv

ed

Re

se

rv

ed

SReg Int

gRst

SReg Int

gHld

Sp

dRamp Hold

Tim

e A

xis

En

Ta

ch

Lo

ss

R

st

Sp

d S Cr

v E

n

Sp

dRamp D

sbl

Default

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

Bit

15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

0

0 = False
1 = True

Column(s) Explanation

1

No. - Parameter Number


= Parameter value cannot be changed until the drive is stopped.

= Parameter is displayed on the HIM only when Par 196 [ParamAccessLvl] is set to 1 “Advanced”.

2

Name - Parameter name as it appears in the DriveExecutive software.

Description - Brief description of parameter function.

3

Values - Define the various operating characteristics of the parameter.
There are 3 types of Values:

Numeric

Default:

Lists the value assigned at the factory.

Min/Max.

Displays lowest possible setting/Displays highest possible setting.

Units:

Unit of measure and resolution as shown on the LCD HIM.
Important: Analog inputs can be set for current or voltage with parameter 821 [Analog I/O Units].

Scale:

Value sent from Controller or Comm Device = Drive Parameter Value x Comm Scale

ENUM

Default:

Lists the value assigned at the factory.

Options:

Displays the selections available.

Bit

Options:

Displays the bit selections available.

Default:

Lists the value assigned at the factory.

Bit:

Bit number.

Linkable - “Y” indicates that the parameter is linkable.

Read-Write - Identifies if the parameter is read-write or read-only.
RW = Read-Write
RO = Read Only

Data Type - Identifies the parameter data type (i.e. integer, floating point, boolean).

A