Baud rate top of form port mode exit, Baud rate, Top of form – Rockwell Automation 2711 Standard PanelView Operator Terminal User Manual User Manual

Page 103: Port mode, Exit

Advertising
background image

Publication 2711-UM014G-EN-P - September 2008

103

Configuring the Terminal Chapter 3

Baud Rate

Sets the communication rate of the printer port. The communication
rate must match the communication rate of the printer. The
communication rate is adjusted with each key press: 1200, 2400, 4800,
9600, and 19200. The initial default is 9600.

Top of Form

Notifies the PanelView terminal the printer is at the top of a page.

Manually adjust the printer to the top of the page before pressing the
Top of Form button. The printer also uses the Perforation Skip Value
(if defined in the Printer Setup of the PanelBuilder32 software) when
the Top of Form button is pressed.

On powerup, the terminal assumes the printer is at the top of a page.
We recommend that you also set the PanelView terminal to the top of
the page so that the printer and PanelView are at the same starting
point. Otherwise your printout may not start at the top of the page.

Port Mode

Enables or disables printing for the RS-232 port.

The RS-232 port on some terminals supports both printing and
application transfers. If you disable printing, the port is used for
application transfers.

Exit

Returns to the Configuration Mode menu.

Advertising