Connecting a Hand-held Terminal

To connect a Hand-held Terminal (HHT) to the PanelView terminal,
use cable Cat. No. 1747-C10. One end of the cable connects to the
HHT connector and the other end connects to the DH-485
programming connector on the terminal. All power is supplied to the
HHT through the cable.

IMPORTANT

The PanelView terminal must be connected to an SLC, DH-485
network, or power supply. This connection provides power for
the HHT.

PanelView 1000

Hand-Held Terminal

Catalog No. 1747-PT1

To DH-485 Programming

Connector

DH-485 Communication Port Must be
connected to an SLC, DH-485 network, or
wallmount power supply (Cat. No. 1747-NP1) to
provide power for the HHT.

Cable, 2 m (6 ft) Cat. No. 1747-C10