Configure presets, Power-up with presets or last states, Restart unit and load values – Rockwell Automation 2711 Standard PanelView Operator Terminal User Manual User Manual

Page 88

Advertising
background image

88

Publication 2711-UM014G-EN-P - September 2008

Chapter 3 Configuring the Terminal

Restart Terminal

Resets the terminal.

Exit

Returns to the Configuration Mode menu.

Configure Presets

Select Preset Operations from the Configuration Mode menu to set the
values of control objects after a reset or power cycle. You can set
presets to:

values provided by the PanelView application.

last values entered from terminal prior to a reset or power
down.

Power-up with Presets or Last States

Displays the current power-up selection. Use the up and down arrow
keys on keypad terminals (or the up and down keys on touch screen
terminals) to select an option. The selection takes effect the next time
the terminal is powered on.

Select Presets to load initial values of control objects (into
controller data tables) with values supplied by the application.

Select Last States to load initial values of control objects (into
controller data tables) with values entered at the terminal prior
to a terminal reset or power down.

Restart Unit and Load Values

Loads the values selected in the Power-up With list and resets the
terminal.

PRESET OPERATIONS

Last States

Presets

Key Repeat

Rate

1000 ms

F7

Key Repeat

Delay

200 ms

F15

Restart Unit

And

Load Values

F1

Power Up With:

F16

EXIT