Publication 2711-UM014G-EN-P - September 2008

Chapter 12 Terminal Connections

Supported Controllers

The remote I/O terminal connects to any Allen-Bradley 1771 remote
I/O link. Applicable host controllers include almost all Allen-Bradley
PLCs, computers, VME controllers, and DEC Q-Bus controllers with a
remote I/O scanner module. New PLC product releases that support
1771 remote I/O will also work with PanelView.

When connecting a PanelView terminal to a controller refer to the
user manual for your controller or scanner module for connection
diagrams and any remote I/O limitations. The table below provides a
summary of possible connections.

Controller

Scanner

Comments

ControlLogix

1756-DHRIO

Connect PanelView terminals through the 1756-DHRIO module.

PLC-5/11, 5/15

(1)

,

5/20, 5/25,
5/30, 5/60, 5/80,
5/250

PLC Integral 1771-SN

Connect PanelView terminals directly to the remote I/O port (scanner
mode). Connect PanelView terminals through the 1771-SN
subscanner module.

PLC-5/10, 5/12

1771-SN

Connect PanelView terminals through the 1771-SN subscanner
module.

PLC-2

1771-SN or 1772-SD2

(2)

Connect PanelView terminals to the PLC-2 family of processors
through a 1771-SN I/O subscanner module.

PLC-3 and
PLC-3/10

None
PLC-3/10
remote I/O Scanner

(3)

Connect PanelView terminals directly to a PLC-3.
Connect PanelView terminals to the PLC-3/10 through the remote I/O
scanner.

SLC-5/02, 5/03, 5/04,
5/05

1747-SN

Connect PanelView terminals through the 1747-SN subscanner
module. Each module provides an additional remote I/O link for up to
4 racks.

Important: Only Series B and later versions of the 1747-SN
subscanner support block transfers.

IBM PC

6008-SI

6008-SI I/O scanner is compatible with IBM PC or compatible
computers. The scanner provides a computer access to the 1771
remote I/O link.

VME

6008-SV

6008-SV I/O scanner provides access to the 1771 remote I/O link for
VME controllers.

DEC Q-BUS

6008-SQ

6008-SQ I/O scanner provides access to the 1771 remote I/O link for
DEC Q-BUS controllers.

(1)

If using a PLC-5/15 with partial rack addressing and block transfers, you must use Series B, Rev. J or later.

(2)

If using a 1772-SD2 Remote Scanner/Distribution Panel, use revision 3 or later.

(3)

If using a 1775-S4A Remote Scanner/Distribution Panel, user Series B or later.