TECHNICAL NOTE


See below for a table of RDA values:


Table: Axis #1 RDA values from SVON Axis Mapping

Run Status-1

MW30200

IW8000 - Run Status

Run Status-2

MW30201

IW800C - Position Status

Servo Status

MW30202

IW802C - Servo Status

MW30203

-

Target Position

ML30204

IL8010 - Target Position

Latched Position

ML30206

IL8018 - Latched Position

Actual Position

ML30208

IL8016 - Acutal Position

Command Status

MW30210

IW8009 - Motion Command Status

Command Response

MW30211

IW8008 - Motion Command Response

Alarms

ML30212

IL8004 - Alarm

Warning

ML30214

IL8002 - Warning

Servo Alarm Code

MW30216

IW802D - Servo Alarm Code

Servo DI Monitor

MW30217

IW802E - Servo DI Monitor

Speed Ref. Monitor

ML30218

IL8020 - Speed Reference Monitor

Feedback Speed

ML30220

IL8040 - Feedback Speed Monitor


• If the servo is disabled while motion is in progress (OW**08<>0), the servo axis

will generate an error (IB**2C0), and an error bit will be set in the RDA
(MB3**81D). A SVON block fault will not occur until the next enable attempt. To
correct this, clear the alarm using the alarm reset function block, BALRMRST.

• The AXISEND block MUST be used in conjunction with this function block.

• Forty-six words are used as working registers for this function, starting at the

address in Data46W.


File: MP2000_IndividualFunctionDocument_RevC 108/168