Aenc_rst> input and output register map, Output, Type – Yaskawa MP2000 User Manual

Page 118: Description, Running, Done, Error, Execute, Axis, Data05w

Advertising
background image

TECHNICAL NOTE

• If EXECUTE has been turned ON, But the Absolute encoder rest operation does

not complete within 5 seconds, ERROR output bit will turn ON. For the time
between the EXECUTE ON and the ERROR output bit turns ON, the RUNNING
output bit will be ON

• Five words are used as working registers for this function, starting at the address

in Data05W


<AENC_RST> Input and Output Register Map


Output Registers
The following registers are used as outputs from the function block. They can be
monitored by the LadderWorks program to check the execution of the function.

Output Type

Description

RUNNING

Bit

High while block has control and Absolute
Encoder Reset Procedure is in process

DONE

Bit

Indicates the Absolute Encoder Reset
Procedure has completed successfully

ERROR

Bit

Latches high if any error occurs in block.



Input Registers
The following registers are used as inputs to the function block. They select the options
and

EXECUTE

Bit

Block enable – Block cannot
execute unless this is
TRUE.

Rising edge initiates
TRUE – Block enable
FALSE – Block disable, set
all outputs to zero and off

AXIS

Word

Axis number related to the
block.

1 to 16

DATA05W

Addres
s

Address of the first working
register.

Five (5) words of register
space are used by this
function.

Input

Type

Description

Range and state

File: MP2000_IndividualFunctionDocument_RevC 118/168
Doc Number: eng.MCD.05.101

11/17/2005

Advertising