TECHNICAL NOTE

(c) DEC 1+ZERO signal method

The movement starts at the speed of the homing in the direction specified by the parameter.

When the rising edge of the DEC1 signal is detected, speed is decelerated to the approach speed.
Speed is decelerated to the creep speed at the rising edge of the ZERO signal after DEC1 is
passed at the approach speed, and final positioning is performed. The machine coordinate
system is established with the position to be the HOME .
The amount of the movement from the ZERO signal is set in the final travel distance of homing.
When the OT signal is detected while in homing process, it becomes OT alarm.



















Input

Name

Set content

EXECUTE Execution

Block enable

REVERSE Direction

selection

The direction of the homing.
0: Seek in forward
1: Seek in reverse

INPUT

INPUT input

Not used

AXIS

Axis setting

Axis number related to the block.
1~16

TYPE

Home position
return method

2: "DEC+ZERO signal" method is selected.

TIME

Timer limit
setting

Maximum time to complete the Homing, if timeout
then Error

TRAVSPD Speed of rapid

feed

Traverse speed in count/second.
0-Max speed (ML3**12)

APRSPD

Approach
speed

Approach speed in count/second.
0-Max speed (ML3**12)

CRPSPD

Creep rate

Creep speed in count/second.
0-Max speed (ML3**12)

OFFSET

Offset value

Final moving distance. And the position will be this
value. If the value is positive, the final moving is in
the same direction of homing. If it is negative the
final moving will be in the opposite of homing