Asciiout> block fault conditions, Asciiout> working register – Yaskawa MP2000 User Manual

Page 162

Advertising
background image

TECHNICAL NOTE

<ASCIIOUT> Block Fault Conditions:

The following table outlines several situations that may cause an error, and will turn on
the blocks “Error” output bit. The block “Error” output will OFF if the EXECUTE bit goes
low.

Internal Fault Bit

Cause

Note

inRng1
AB000003

Improper cir
number. Out of
range.

On the initial pass of the block the bit must
be high or an error will occur. Sets RDA
Error ID (MW3**81) bit 3 on if error state
exists.

inRng2
AB000004

Improper slave
address

On the initial pass of the block the bit must
be high or an error will occur. Sets RDA
Error ID (MW3**81) bit 3 on if error state
exists.

snderr
AB00001F

MSG-SND has an
error.

The MSG-SND internal function has an
error. Refer to ERROR-ID output for
value.
81= function code error
82= address set error
83= data size error
84= line number set error
85= channel number set error
86= station address error
88= transmission part error
89= device selection error


<ASCIIOUT> Working Register

This table outlines the data in the Twenty-three registers used by the function block.
There is not usually any need for the user to access any of these bits directly. The
MSG-SND type registers can be further understood by referencing the MSG-SND
function block in the on line help.

Register No

Type

Name

Description

AW00000

Bit 0

IN

execute

EXECUTE input (XB000000)

Bit 1

Working

crlf

If True, a carriage return and Line feed are inserted at the end
of the table.

Bit 2

Working

oddnum

Reserved

Bit 3

OUT

inRng1

Verifies that CIR-NUM input (XW00003) is in range

Bit 4

OUT

inRng2

Verifies that SLAVE input (XW00004) is in range

Bit 7

OUT

running

Directly controls YB000000 (RUNNING Output)

Bit 8

OUT

done

Directly controls YB000001 (COMPLETE Output)

Bit 9

OUT

error

Directly controls YB000002 (ERROR Output)

Bit A

Working

oneshotA

Reserved

Bit B

Working

firstPass

One shot on rising edge of EXECUTE input to initialize RDA &
sets parameters in the message send function

File: MP2000_IndividualFunctionDocument_RevC 162/168
Doc Number: eng.MCD.05.101

11/17/2005

Advertising