Asciiout> application example, Hardware setup – Yaskawa MP2000 User Manual

Page 164

Advertising
background image

TECHNICAL NOTE

File: MP2000_IndividualFunctionDocument_RevC 164/168
Doc Number: eng.MCD.05.101

<ASCIIOUT> Application Example:

The following example illustrates how to send characters from Port #1 of an MP2300 217IF-01
module (in the first slot) to COM1 of a PC via RS232 . MotionWorks is used to set the
Character table data in registers MW04000 through MW04007 (16 characters). Hyper-
terminal

tm

is used to receive and display the character string.

Hardware setup

The second slot
Port1-PC COM2
Cable for MPE720
communication
W5311-03

The first slot
Port1-PC COM1
Cable for ASCII
communication

Yaskawa W5311-03 cable is connected from Port#1 of
the MP2300 217IF-01 module (the second slot) to PC
COM2 for MotionWorks interface software.
Port#1 of the MP2300 217IF-01 module (the first slot)
and PC COM1 are connected for ASCII communication
(refer to the user's manual for wiring).









MP2300 MotionWorks Software Module setup











Setting the serial interface of MP2300 217IF-01
module Port#1 (the first slot) for ASCII communication
is as follows.

Note that Transmission protocol is set

to None. Master/Slave and Serial I/F settings are
not used so they will be ignored . Protocol settings
are as follows:

Transmission protocol: No procedure
Transmission mode: None
Data length: 8bit
Parity bit: Even
Stop bit: 1 Stop
Baud rate: 9600bps