TECHNICAL NOTE

(b) ZERO signal method

The movement starts at the approach speed in the direction specified by the parameter. Speed

is decelerated to the creep speed at the rising edge of the ZERO signal and finishes positioning.
The machine coordinate system is established with the position to be the HOME.
The amount of the movement from the ZERO signal is set in the final travel distance of homing.
When the OT signal is detected while in homing process, it becomes OT alarm.



















Input

Name

Set content

EXECUTE

Execution

Block enable

REVERSE

Direction
selection

The direction of the homing.
0: Seek in forward
1: Seek in reverse

INPUT

INPUT input

Not used

AXIS

Axis setting

Axis number related to the block.
1~16

TYPE

Home position
return method

1: "ZERO signal" method is selected.

TIME

Timer limit
setting

Maximum time to complete the Homing, if timeout then
Error

TRAVSPD

Speed of rapid
feed

Not used

APRSPD

Approach speed Approach speed in count/second.

0-Max speed (ML3**12)

CRPSPD

Creep rate

Creep speed in count/second.
0-Max speed (ML3**12)

OFFSET

Offset value

Final moving distance. And the position will
be this value. If the value is positive, the
final moving is in the same direction of
homing. If it is negative the final moving will
be in the opposite of homing


File: MP2000_IndividualFunctionDocument_RevC 49/168