TECHNICAL NOTE

File: MP2000_IndividualFunctionDocument_RevC 20/168
Doc Number:

EF.MCD.05.101

11/17/2005

Bit E

Working

cmndError

One shot coil for when another block takes control
from this block.

Bit F

Working

direrr

On if a direction is commanded that is not enabled
by the SVON block.

AW00002

Working

mstr_slave

MstrSlave [value of (XW00001) – 1]

AW00003

Working

filter1

Temporary values used to filter bits.

AW00004

OUT

camstate

Directly controls YW00001 (STATE Output).

AW00005

Bit 0

Working

axisInErr

Goes high for one scan if Axis input is out of range.

AL00006

Working

yFirst

First position of slave in Cam table.

AL00008

Working

yLast

Last position of slave in Cam table.

AL00010

Working

xLast

Last position of Master in Cam table.

AL00012

Working

lastAddress

Final register address of Cam table.

AL00014

Working

Window

Tolerance value for engage and disengage
position. Divide XLAST by 120. IE – this window
is 0.8% of the machine cycle.

AL00016

Working

masterpos

Value of Master after CAM shift.

AL00018

Working

engage_differe
nce

Distance from engage or disengage point.

AL00020

Working

base_slave_po
s

Reserved

AL00022

Working

fgnOut

Value returned from Cam table function generator

AL00024

Working

slave_Pos_Cm
nd

Reserved

AL00026

Working

deltaY

Difference between first and last slave position in
table, used if it’s a one-way cam to offset the slave

AW00028

Bit 0

Working

ESTOP_Latch Latch

E-stop

Condition

Bit 1

Working

RECV_MODE

In Recovery Motion

Bit 2

Working

RECV_COMP

Recovery Motion Complete

Bit 3

Working

Oneshot283 Reserved

Bit 4

Working

Oneshot284 Reserved

Bit 5

Working

RECV_SHOT

Reset Error after Recovery motion is done

AW00029

Working

Timer

Positioning Completion Timer for E-Stop recovery

AW00030

Working

rdaMult

Value for address offset to locate proper RDA

AW00031

Working

Revision

Revision Level of Block.




Advertising