Tuning>input and output register map – Yaskawa MP2000 User Manual

Page 114

Advertising
background image

TECHNICAL NOTE

• Six words are used as working registers for this function, starting at the address

in Data06W.


<TUNING>Input and Output Register Map


Output Registers
The following registers are used as outputs from the function block. They can be
monitored by the LadderWorks program to check the execution of the function.

Output Type

Description

RUNNING

Bit

This bit is ON when the function block is
executing.

DONE

Bit

This bit is ON when the function block is
complete and there are no errors

ERROR

Bit

This bit is ON when one of the values is out of
range. However, if the error condition is
cleared, this output is reset to OFF.







Input Registers
The following registers are used as inputs to the function block. They select the options
and define the parameters that the user needs to make the function work as necessary.

INPUT

TYPE

Content

Range of setting and state

EXECUTE Bit

Block enable – Block cannot
execute unless this is
TRUE.

Rising edge initiates block
TRUE – Block enable
FALSE – Block disable, set
all outputs to zero and off

AXIS

Word

Axis number related to the
block

1~16

FEEDFWD Word

Speed Feed forward

0~100[%]
Set parameter OWxx30

SPDLOOP Word

Speed loop gain

1~2000[Hz]
Set parameter OWxx2F

POSLOOP Word

Position loop gain

10~20000[0.1/s]
Set parameter OWxx2E

SPD-TI

Word

Speed loop integral time
constant

15~32767[0.01ms]
Set parameter OWxx34

POS-TI

Word

Position loop integral time
constant

0~5000[ms]
Set parameter OWxx32

DATA06W

Address

Address of the first working
register.

Six words of register space
are used by this function.

File: MP2000_IndividualFunctionDocument_RevC 114/168
Doc Number: eng.MCD.05.101

11/17/2005

Advertising