MODULUS ENGINE function

Function block for MP2000 series


<MOD_ENG> Function Block Summary

The “MOD-ENG” block is used to modulate any counter (true encoder or virtual counter) into a saw tooth
shape pattern with a cycle equivalent to the machine cycle desired (see diagram below). The machine
cycle is the highest value the output can go before it returns to zero. This block stores its data in the RDA
based on its Master/Slave value. This block is required for the Cam function block to work.

Function Block Diagram
















<MOD_ENG> Function Block Operation Notes

• This block should be used with CAM function block.

• To use the function block, the ENABLE bit must be held ON. The block will begin

to execute (output the modulated RAWDATA input) on a rising edge from the
EXECUTE

bit.

• If

the

ENABLE

bit goes off during operation, the Raw data as well as the

modulated data will stop being sent to the RDA and all outputs will go to zero.

• The

RESET

bit sets the modulated data to zero.

• Note that the master/slave pairs are separated by 50 words in the RDA(up to 10

pairs). Example: Master/Slave pair #1 starts at MW56000, Master/Slave
pair #2 starts at MW56050, Master/Slave pair #3 starts at MW56100, etc

• Fourteen words are used as working registers for this function, starting at the

address in Data14W.