Rda initialization #1 function, Rdainit1> function block summary, Rdainit1> function block operation notes – Yaskawa MP2000 User Manual
Page 130: Rdainit1

TECHNICAL NOTE
RDA INITIALIZATION #1 Function
Function block for MP2000 series
<RDAINIT1> Function Block Summary
The Reserved Data Area (RDA) Initialization function block (RDAINIT1) block is used to initialize the
values in the RDA for a specific axis. Without the proper values in the RDA the some motion blocks may
not work properly. The RDAINIT2 block must also be used to complete the initialization of all mandatory
RDA values.
Function Block Diagram
<RDAINIT1> Function Block Operation Notes
• To use the function block, it must be placed in an ‘A’ drawing.
• Both RDA init 1 and 2 blocks should be used together for each axis. RDA Init 1
block sets Linear or Rotary positioning mode, Maximum Speed/Accel/Decel/Jerk
values, and the rotary position period.
• This drawing uses no drawing registers to run.