TECHNICAL NOTE

<TUNING> Working Registers

This table outlines the data in the six registers used by the function block. There is not
usually any need for the user to access any of these bits directly.

Register No

TYPE

Name

Content

AW00000

Bit 0

IN

execute

EXECUTE input (XB000000)

Bit 1

Working

feedfwdOut

Goes high for one scan if FEEDFWD input is out of range.

Bit 2

Working

spdLoopOut

Goes high for one scan if SPDLOOP input is out of range.

Bit 3

Working

posLoopOut

Goes high for one scan if POSLOOP input is out of range.

Bit 5

Working

axisInErr

Goes high for one scan if Axis input is out of range.

Bit 6

Working

RDA_Error

Goes High if RDA module or axis number is not in range.

Bit 7

OUT

running

Directly controls YB000000 (RUNNING Output)

Bit 9

OUT

error

Directly controls YB000002 (ERROR Output)

Bit A

Working

osExecute

Reserved

Bit B

Working

firstPass

One shot coil for initializing block on the rising edge of the
EXECUTE input.

AW00001

Bit 9

Working

SPDTiout

Goes high for one scan if SPD-TI input is out of range.

Bit A

Working

PosTiOut

Goes high for one scan if POS-TI input is out of range.

Bit C

Working

oneshot1c

Reserved

Bit D

Working

Done_latch

Directly controls YB000001 (DONE Output)

AW00003

Working

rdaMult

Value for address offset to locate proper RDA

AW00004

Working

axisMult

Value for address offset to locate proper Axis

AW00005

Working

revision

Revision level of block.










File: MP2000_IndividualFunctionDocument_RevC 116/168
Doc Number: eng.MCD.05.101

11/17/2005