Movinc> block error condition – Yaskawa MP2000 User Manual
Page 93
 
TECHNICAL NOTE
<MOVINC> Block error condition:
The following tables might cause the error, and outline some situations. If the 
EXECUTE input bit is turned off, the value is cleared. 
Internal error bit
Cause
Attention
errStop 
AB00000D 
Motion 
commanded and 
servo is faulted 
If block is running and the servo is faulted 
the error bit will be set. Sets RDA Error ID 
(MW3**81) bit B on if error state exists. 
axisInErr 
AB000002 
 
The axis number 
entered on the 
input is not an 
acceptable value 
The function blocks can only control 1 to 
16 axes. Any value greater or smaller 
then this will cause an error. This does 
not set the RDA Error ID. 
Commanderr 
AB00000E 
Another block took 
control of the axis 
If the block looses control of the axis while 
running an error will occur. This does not 
set the RDA Error ID. 
Direrror 
AB00000F 
The direction 
commanded to 
travel is disabled 
from the SVON 
block. 
The SVON block must be used and have 
the direction commanded enabled. Sets 
RDA Error ID (MW3**81) bit 4 on if error 
state exists. 
 
 
 
 
 