Yaskawa MP2000 User Manual
Page 157

TECHNICAL NOTE
AW00010
MSG-RCV
Reserved
Reserved
AW00011
MSG-RCV
Reserved
Reserved
AW00012
MSG-RCV
holding_offset
Value to shift data in register (Param11, this is
meaningless for non-protocol mode)
AW00013
MSG-RCV
starAddress
First address of M register to store data (This sets
Param12)
AW00014
MSG-RCV
endAdd
End address of M register to store data (this sets
param13)
AW00015
MSG-RCV
system
Reserved
AW00016
MSG-RCV
Reserved
Reserved
AW00017
MSG-RCV
Reserved
Reserved
AW00018
Working
Reserved
Reserved
AW00019
Working
Reserved
Reserved
AW00020
OUT
errorID
Directly controls ERROR-ID output (YW00001)
AW00021
Working
iStore
Reserved
AW00022
Working
step
Reserved
AW00023
Working
endAddress
Final M register to store data
AW00024
Working
Reserved
Reserved
AW00025
Working
Reserved
Reserved
AW00026
Working
filterLow
Reserved
AW00027
Working
filterHigh
Reserved
AW00028
OUT
chrCount
Number of Characters received Directly controls
ERROR-ID
output (YW00001).
AW00029
Working
Revision
Revision Level of the function block.
File: MP2000_IndividualFunctionDocument_RevC 157/168
Doc Number: eng.MCD.05.101
11/17/2005