Lthtrgt> block error condition, Lthtrgt> working registers, Startpos – Yaskawa MP2000 User Manual

Page 76: Distgone, Rdamult, Revision

Advertising
background image

TECHNICAL NOTE

<LTHTRGT> Block error condition:

The following table outlines several situations that may cause an error, and will turn on
the blocks “Error” output bit. The block “Error” output will cleared if the EXECUTE bit
goes low.

Internal error bit

Cause

Attention

errStop
AB000005

Motion
commanded and
servo is disabled.

If block is running and the servo is
disabled the error bit will be set. Sets RDA
Error ID (MW3**81) bit B on if error state
exists.

commanderr
AB00000E

Another block took
control of the axis.

If the block looses control of the axis while
running an error will occur. This does not
set the RDA Error ID.

direrror
AB00000F

The direction
commanded to
travel is disabled
from the SVON
block.

The SVON block must be used and have
the direction commanded enabled. Sets
RDA Error ID (MW3**81) bit 4 on if error
state exists.

axisInErr
AB000083

The axis number
entered on the
input is not an
acceptable value

The SVB multiaxis blocks can only control
1 to 16 axes. Any value greater or smaller
then this will cause an error. This does not
set the RDA Error ID..


<LTHTRGT> Working Registers

This table outlines the data in the twelve registers used by the function block. There is
not usually any need for the user to access any of these bits directly.

Register No

TYPE

Name

Content

AW00000

Bit 0

IN

execute

EXECUTE

input (XB000000)

Bit 3

Working

latched

Goes high for one scan, if a latch occurs inside the latch
activation window (one-shot)

Bit 4

Working

oneshot

Reserved.

Bit 5

Working

errStop

Goes high if servo faults out while running.

Bit 6

OUT

Latched

Directly controls YB000002 (LATCHED Output)

Bit 7

OUT

running

Directly controls YB000000 (RUNNING Output)

Bit 8

OUT

complete

Directly controls YB000001 (DONE Output)

Bit 9

OUT

error

Directly controls YB000003 (ERROR Output)

Bit A

Working

oneshotA

Reserved

Bit B

Working

firstPass

One shot coil for initiating axis and block.

Bit C

Working

oneshotC

Reserved.

Bit E

Working

commanderr

Rising Edge indicates another block took control.

Bit F

Working

direrror

Indicates direction commanded is not enabled.

AL00002

Working

startpos

Value of axis position at start of move.

AL00004

Working

distGone

Directly controls YL000001 (DISTGONE Output)

AW00009

Working

rdaMult

Value for address offset to locate proper RDA

AW00010

Working

Revision

Revision Level of the function block.

File: MP2000_IndividualFunctionDocument_RevC 76/168
Doc Number: eng.MCD.05.101

11/17/2005