Def_pos> input and output register map, Output, Type – Yaskawa MP2000 User Manual

Page 126: Description, Done, Running, Error, Input, Execute, Abenc

Advertising
background image

TECHNICAL NOTE

• Ten words are used as working registers for this function, starting at the address

in Data10W

<DEF_POS> Input and Output Register Map


Output Registers
The following registers are used as outputs from the function block. They can be
monitored by the LadderWorks program to check the execution of the function.

Output Type

Description

DONE

Bit

Indicates the Define Position Procedure has completed
successfully

RUNNING

Bit

Indicates the Define Position Procedure is in process.

ERROR

Bit

Latches high if any error occurs in block.








Input Registers

The following registers are used as inputs to the function block. They select the options
and set necessary parameters internally.

Input

Type

Description

Range and State

EXECUTE

Bit

Block enable – Block cannot
execute unless this is TRUE.

Rising edge initiates
TRUE – Block enable
FALSE – Block disable, set all
outputs to zero and off

ABENC

Bit

For power up operational
purposes the existence of
Absolute Encoder on this axis
needs to be known.

TRUE – An absolute encoder is
mounted on the servomotor for this
axis.
FALSE – An incremental encoder
is mounted on the servomotor for
this axis.

AXIS

Word

Axis number related to the block.

1 to 16

REQPOSIT Long

The Desired Position the Axis is
to be set at.

For linear axis, the value can be
–2

31

to (2

31

–1)

For a Rotary Axis the value must
be 0 to the PERIOD (ML***06)
defined in the RDA

DATA10W

Address

Address of the first working
register.

Ten (10) words of register space
are used by this function.










File: MP2000_IndividualFunctionDocument_RevC 126/168
Doc Number: eng.MCD.05.101

11/17/2005

Advertising