<WRTPARAM> Block Fault Condition:

The following table outlines several situations that may cause an error. The block error
can be cleared by the EXECUTE bit going low

Fault Bit

Cause

Note

axisInErr
AB00000F

The axis number
entered on the
input is not an
acceptable value

The function blocks can only control 1 to
16axis. Any value greater or smaller then
this will cause an error. This does not set
the RDA Error ID.

Notspec
AB00000E

Parameter
specified is not a
valid RDA number

The number specified must be either the
Yaskawa specified RDA area or the
PLCOpen specified area. This block can
not monitor Master/Slave data. Sets RDA
Error ID (MW3**81) bit 3 on if error state
exists.

valueOut
AB00000D

Value out of range
for the RDA

Value must be within range of value being
stored or error will occur. Sets RDA Error
ID (MW3**81) bit 3 on if error state exists.


<WRTPARAM> Working Registers

This table outlines the data in the six registers used by the function block. There is not
usually any need for the user to access any of these bits directly.

Register No

TYPE

Name

Content

AW00000

Working

Reserved

Reserved

AW00001

Working

Reserved

Reserved

AW00002

Working

iStore

Reserved

AW00003

Working

ivalue

Reserved

AW00004

Working

rdaMult

Value for address offset to locate proper RDA

AW00005

Working

Revision

Revision Level of the function block.

File: MP2000_IndividualFunctionDocument_RevC 150/168
Doc Number: eng.MCD.05.101

11/17/2005