Camoffst> block fault condition, Camoffst, Block fault condition – Yaskawa MP2000 User Manual
Page 24
 
TECHNICAL NOTE
File: MP2000_IndividualFunctionDocument_RevC 24/168 
Doc Number: 
EF.MCD.05.101
11/17/2005
Input Registers
The following registers are used as inputs to the function block. They select the options 
and define the parameters that the user needs to make the function work as necessary. 
Input
Type
Description
Range and state
EXECUTE
Bit
Block enable – Block cannot 
execute unless this is 
TRUE. 
Rising edge initiates block
TRUE – Block enable
FALSE – Block disable, set all 
outputs to zero and off 
DST-TIME
Bit
Selects master or time for 
offset duration 
TRUE – Master position is 
used for duration 
FALSE – Time is used for 
duration. 
M-S-PAIR
Word
Defines which Master-Slave 
pair is updated in RDA 
1 to 10 value. Any other 
value will cause the error 
output to go on 
DURATION Long
Depends on DST-TIME 
setting. Either time in msec 
or distance master must 
travel to complete change in 
offset. 
 -2147483648 to 
2147483647. 
If in time mode no negative 
numbers are allowed. 
OFFSET
Long
Relative shift to be applied 
to the master. RDA will hold 
absolute offset value level 
(The RDA offset is ML56**4) 
-2147483648 to 2147483647
DATA23W
Address Address of the first working
register.
Twenty-three words of 
register space are used by 
this function. 
<CAMOFFST>
Block Fault Condition
The following table outlines several situations that may cause an error, and will turn on 
the blocks “Error” output bit. The block “Error” output will cleared if the EXECUTE bit 
goes low, but the Error ID (MW3**81and MW3**82) will remain in the RDA. To reset the 
Error ID, use the Alarm Reset Function Block. 
The following table outlines several situations that may cause an error. 
Internal Fault bit
Cause
Note
Inrng1 
AB00000E 
MSTRSLV value 
out of range 
Inrng1 must be high if execute is on or an 
error will occur. MSTRSLV must have a 
value from one to ten for this bit to be on. 
Sets RDA Error ID (MW30181) bit 3.