Move incremental function, Movinc> function block summary, Movinc> function block operation notes – Yaskawa MP2000 User Manual
Page 91: Movinc
 
TECHNICAL NOTE
MOVE INCREMENTAL function
Function block for MP2000 series
 
<MOVINC> Function Block Summary 
This function block commands a controlled motion of a specified distance relative to the actual position at 
the time of the execution. 
Function Block Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
<MOVINC> Function Block Operation Notes
• MOVINC must be in H drawing, and to be executed after execution of SVON and
CHANGE DYNAMICS function.
• Rising edge of EXECUTE input initiates block operation, and all block input
values are read.
• The
RUNNING
output bit will be held high until: move is completed, EXECUTE
goes low, or an Error occurs
• DONE bit turns on when positioning is completed (IB**0C1=ON). When
distributing target position and the current position is within the range of the 
positioning complete (target position ± positioning completed width), the 
positioning completed becomes High. 
• If another block takes control of the axis while the block is running a command
error will occur. The ERROR output will go on, but the RDA will not indicate an 
error. 
• The S-curve, Acceleration, Deceleration and the Speed will be set based on the
values in the RDA, set by Change Dynamics Block.
• Eight words are used as working registers for this function, starting at the
address in Data08W.
 
 
File: MP2000_IndividualFunctionDocument_RevC 91/168 
Doc Number: eng.MCD.05.101 
11/17/2005