TECHNICAL NOTE

<WRTPARAM> Parameter list

The following table shows the accessible parameters by RDPARAM. #001 through #999
are PLCOpen specification and above #1000 are supplier specific..

RDA#

Data name

Details

005 Movement Type

0: Rotor 1: Liner

006 Position Period

Length of Period for rotational systems. [count]

007 Set Position

Commanded position. [count]

008 Act Position

Actual position. [count]

009 Max Velocity

Maximum velocity. [count/sec]

010 Set Velocity

Commanded velocity. [count/sec]

011 Act Velocity

Actual Velocity of axes. [count/sec]

012 Set Acceleration

Commanded acceleration. [count/sec

2

]

013 Act Acceleration

Actual acceleration. [count/sec

2

]

014 Max Acceleration

Maximum acceleration. [count/sec

2

]

015 Set Deceleration

Commanded deceleration. [count/sec

2

]

016 Act Deceleration

Actual deceleration. [count/sec

2

]

017 Max Deceleration

Maximum deceleration. [count/sec

2

]

018 Set S-Curve Filter

Commanded S-Curve Filter [ms] (S curve time)

019 Act S-Curve Filter

Actual S-Curve Filter [ms] (S curve time)

020 Max S-Curve Filter

Maximum S-Curve filter [ms] (S curve time)

021 Act Torque

Actual Torque [0.01% of rated torque]

027 HW Limit Enable

Enable / disable hardware end switch (to be used after

)

028 Capt Position

Capture position [count]

029 Capture Occurred

Capture signal occurred (reset with writing)

030 Ramp Shape

Shape of Acc/Dec profile.
0 = Trapezoid; 1= S-Shape; rest supplier dependent

031 Axis State

State of the Axis
0: reserved for power off situation
1:ErrorStopped Motion
2: Stopped Motion
3: Standstill
4: Discrete motion
5: Continuous motion







File: MP2000_IndividualFunctionDocument_RevC 151/168