Home> homing type, 1) homing type option – Yaskawa MP2000 User Manual

Page 47

Advertising
background image

TECHNICAL NOTE

<HOME> Homing Type


(1) Homing Type Option

The following table shows thirteen Homing Type. Please select the best one for the
machine.

TYPE

Name

Method

Note

0

DEC1+C phase pulsed
system

Three step deceleration method with
deceleration limit switch and C phase
pulse.

DEC1 signal: DEC signal
of the servo amplifier.

1

ZERO signaling system Homing method with ZERO signal.

ZERO signal: EXT1
signal of the servo
amplifier.

2

DEC 1+ZERO signaling
system

Three step deceleration method with
deceleration limit switch and ZERO signal

DEC1 signal: DEC signal
of the servo amplifier.
ZERO signal: EXT1
signal of the servo
amplifier.

3

C phase pulsed system Homing method with C phase pulse

11

C phase pulse

Method only with C phase pulse

12

POT & C phase pulse

Method with positive OT signal and C
phase pulse

POT: POT signal of the
servo amplifier.

13

POT

Method only with positive OT signal

POT: POT signal of the
servo amplifier.
This method is not
applicable if repeatability
is required.

14

HOME LS&C phase
pulse

Method with HOME signal and C phase
pulse

HOME: EXT1 signal of
the servo amplifier.

15

HOME LS

Method only with HOME signal

HOME: EXT1 signal of
the servo amplifier.

16

NOT&C phase pulse

Method with reverse OT signal and C
phase pulse

NOT: NOT signal of the
servo amplifier.

17

NOT

Method only with reverse OT signal

NOT: NOT signal of the
servo amplifier.
This method is not
applicable if repeatability
is required.

18

INPUT & C phase pulse Method with INPUT signal and C phase

pulse

INPUT: INPUT signal

19

INPUT

Method only with INPUT signal

INPUT: INPUT signal
This method is not
applicable if
repeatability is required.

File: MP2000_IndividualFunctionDocument_RevC 47/168
Doc Number: eng.MCD.05.101

11/17/2005

Advertising