Home> homing type, 1) homing type option – Yaskawa MP2000 User Manual
Page 47
 
TECHNICAL NOTE
<HOME> Homing Type
 
(1) Homing Type Option 
 
The following table shows thirteen Homing Type. Please select the best one for the 
machine. 
 
TYPE
Name
Method
Note
0
DEC1+C phase pulsed 
system 
Three step deceleration method with 
deceleration limit switch and C phase 
pulse. 
DEC1 signal: DEC signal 
of the servo amplifier. 
1
ZERO signaling system Homing method with ZERO signal.
ZERO signal: EXT1 
signal of the servo 
amplifier. 
2
DEC 1+ZERO signaling 
system 
Three step deceleration method with 
deceleration limit switch and ZERO signal 
DEC1 signal: DEC signal 
of the servo amplifier. 
ZERO signal: EXT1 
signal of the servo 
amplifier. 
3
C phase pulsed system Homing method with C phase pulse
11
C phase pulse
Method only with C phase pulse
12
POT & C phase pulse
Method with positive OT signal and C 
phase pulse 
POT: POT signal of the 
servo amplifier. 
13
POT
Method only with positive OT signal
POT: POT signal of the 
servo amplifier. 
This method is not 
applicable if repeatability 
is required. 
14
HOME LS&C phase 
pulse 
Method with HOME signal and C phase 
pulse 
HOME: EXT1 signal of 
the servo amplifier. 
15
HOME LS
Method only with HOME signal
HOME: EXT1 signal of 
the servo amplifier. 
16
NOT&C phase pulse
Method with reverse OT signal and C 
phase pulse 
NOT: NOT signal of the 
servo amplifier. 
 
17
NOT
Method only with reverse OT signal
NOT: NOT signal of the 
servo amplifier. 
This method is not 
applicable if repeatability 
is required. 
18
INPUT & C phase pulse Method with INPUT signal and C phase
pulse
INPUT: INPUT signal
19
INPUT
Method only with INPUT signal
INPUT: INPUT signal 
This method is not 
applicable if 
repeatability is required. 
File: MP2000_IndividualFunctionDocument_RevC 47/168 
Doc Number: eng.MCD.05.101 
11/17/2005