TECHNICAL NOTE

File: MP2000_IndividualFunctionDocument_RevC 4/168
Doc Number:

EF.MCD.05.101

11/17/2005

<AXISEND> Input and Output Register Map

Output Registers
The following registers are used from the function block as an output. To check the
execution of the function, they can be monitored by the MPE720 program.

Output Type

Description

ERROR

bit

If an error occurs during block execution, this
output bit turns ON, but will reset if error
condition goes away.



Input Registers
The following registers are used to block the function as an input. It is necessary to
select the option, define the parameter, and make these function if necessary by the
user.

Input

Type

Description

Range and state

AXIS

Word

Axis number related to the
block.

1~16


<AXISEND> Block Fault Condition:

The following table outlines several situations that may cause an error. The block error
can be cleared by the ENABLE bit going low.

Error bit of internal

Cause

Attention

axisinerr
ZB000020

The axis number
entered on the
input is not an
acceptable value

Function blocks can only control 1 to 16
axes. Any value greater or smaller then
this will cause an error. This does not set
the RDA Error ID.



<AXISEND> Working Registers

This table outlines the data in the registers used by the function block. There is not
usually any need for the user to access any of these bits directly.

Register No

TYPE

Name

Content

AW00000

Working

Revision

Revision Level of the function block.