(f) POT & C phase pulse method

The movement starts at the approach speed, and moves to the stroke limit in a positive direction.
The movement is reversed when POT signal is detected at the creep speed.
POT signal is passed in reversed direction and C pulse is detected, the final positioning is
performed. The machine coordinate system is established with the position to be the HOME.
The amount of the movement from C phase pulse is set in the final travel distance of homing.
Positioning speed is set in the rapid feed speed.
When the OT signal is detected while moving at the positioning speed, it becomes OT alarm.


Note: The stop method when the OT signal is detected follows the user constant setting of the servo
amplifier.
























Input

Name

Set content

EXECUTE Execution

Block enable

REVERSE Direction

selection

The direction of the homing.
0: Seek in forward
1: Seek in reverse

INPUT

INPUT input

Not used

AXIS

Axis setting

Axis number related to the block.
1~16

TYPE

Home position
return method

12: "POT&C phase pulse" is selected

TIME

Timer limit
setting

Maximum time to complete the Homing, if timeout
then Error

TRAVSPD Speed of rapid

feed

Traverse speed in count/second.
0-Max speed (ML3**12)

APRSPD

Approach
speed

Approach speed in count/second.
0-Max speed (ML3**12)

CRPSPD

Creep rate

Creep speed in count/second.
0-Max speed (ML3**12)

OFFSET

Offset value

Final moving distance. And the position will be this
value. If the value is positive, the final moving is in
the same direction of homing. If it is negative the
final moving will be in the opposite of homing

File: MP2000_IndividualFunctionDocument_RevC 54/168