TECHNICAL NOTE
File: MP2000_IndividualFunctionDocument_RevC 37/168 
Doc Number: 
EF.MCD.05.101
11/17/2005
Input Type
Description
Range and State
EXECUTE
Bit
Block enable – Block cannot execute 
unless this is TRUE. FALSE clears 
all outputs to zero or FALSE. 
Rising edge initiates block 
TRUE – Block enable 
FALSE – Block disable, see block 
operation note for additional info 
GEARIN
Bit
Sets the axis in gearing mode with 
the specified gear ratio. 
Always read when EXECUTE=high 
RISING EDGE- If the execute bit is high 
this will set the axis to be in gearing mode. 
GEAROUT
Bit
Takes the axis out of gearing mode 
and stops the axis with the set 
deceleration value from the RDA 
Always read when EXECUTE=high 
RISING EDGE- If the execute bit is high 
this will set the axis to be in gearing mode. 
RIGID
Bit
Determines weather the block will 
gear with phase lock or strictly speed 
matching. 
Read only on EXECUTE rise edge 
TRUE – Rigid enable 
FALSE – Non-Rigid 
AXIS
Word
Axis number related to the block.
Read only on EXECUTE rise edge 
1 to 16 
M-S-PAIR
Word
Master Slave Pair as defined by the 
RDA 
Read only on EXECUTE rise edge 
1 to 10 integer. This value is needed to 
match the value of the Slave offset function 
block. 
RATIO-N
Word
Numerator value of gear ratio *
Always read when EXECUTE=high 
-32768 to 32767 integer. 
RATIO-D
Word
Denominator value of gear ratio *
Always read when EXECUTE=high 
-32768 to 32767 excluding zero. A zero will 
cause an error 
RAW-DATA Long
Pulse counter of master
Always read when EXECUTE=high 
The (change in this value * RATIO-N) / 
RATIO-D will be the commanded change in 
the Slave. 
DATA35W
Addres
s 
Address of the first working register.
Thirty-five words of register space are used 