Yaskawa MP2000 User Manual

Page 60

Advertising
background image

TECHNICAL NOTE

Input

Name

Set content

EXECUTE

Execution

Block enable

REVERSE

Direction
selection

The direction of the homing.
0: Seek in forward
1: Seek in reverse

INPUT

INPUT input

Not used

AXIS

Axis setting

Axis number related to the block.
1~16

TYPE

Home position
return method

15: “HOME LS" is selected.

TIME

Timer limit
setting

Maximum time to complete the Homing, if timeout then
Error

TRAVSPD

Speed of rapid
feed

Traverse speed in count/second.
0-Max speed (ML3**12)
Moving direction follow the sign of the OFFSET.

APRSPD

Approach speed Not used

CRPSPD

Creep rate

Creep speed in count/second.
0-Max speed (ML3**12)

OFFSET

Offset value

Final moving distance. And the position will
be this value. If the value is positive, the
final moving is in the same direction of
homing. If it is negative the final moving will
be in the opposite of homing

File: MP2000_IndividualFunctionDocument_RevC 60/168
Doc Number: eng.MCD.05.101

11/17/2005