Asciiin> example of application, Hardware setup – Yaskawa MP2000 User Manual

Page 158

Advertising
background image

TECHNICAL NOTE

<ASCIIIN> Example of application:

The following examples illustrates how to receive ASCII characters from PC COM1 to
Port#1 of the MP2300 217IF-01 module (In the First Slot) via RS-232C. MotionWorks is
used to monitor the received Character data in registers MW04032 through MW04039
(16 characters). Hyper-terminal

tm

is used to send the character string in a Text file.

Hardware setup

The second slot Port1-
PC COM2
Cable for MPE720
communication
W5311-03

The first Slot Port1-
PC COM1
Cable for ASCII
communication




o


l

Yaskawa W5211-03 cable connects PC COM2 and
MP2300 217IF-01 module (the second slot) Port#1
f r MotionWorks.
PC COM1 and MP2300 217IF-01 module (The first
s ot) Port#1 is connected for ASCII communication.
Refer to the user's manual for the pin assignment.



MP2300 MotionWorks Software Module Setup












Set the MP2300 217IF-01 module Port#1 (The
first slot) serial interface for ASCII
communication. Note that Transmission protocol
is set to None. Master/Slave and Serial I/F settings
are not used so they will be ignored . Protocol
settings are as follows:
Transmission protocol: No procedure
Transmission mode: None
Data length: 8bit
Parity bit: Even
Stop bit: 1 Stop
Baud rate: 9600bps

File: MP2000_IndividualFunctionDocument_RevC 158/168
Doc Number: eng.MCD.05.101

11/17/2005