Yaskawa MP2000 User Manual
Page 56

TECHNICAL NOTE
Input
Name
Set content
EXECUTE
Execution
Block enable
REVERSE
Direction
selection
The direction of the homing.
0: Seek in forward
1: Seek in reverse
INPUT
INPUT input
Not used
AXIS
Axis setting
Axis number related to the block.
1~16
TYPE
Home position
return method
13: “POT" is set.
TIME
Timer limit
setting
Maximum time to complete the Homing, if timeout then
Error.
TRAVSPD
Speed of rapid
feed
Traverse speed in count/second.
0-Max speed (ML3**12)
APRSPD
Approach speed Approach speed in count/second.
0-Max speed (ML3**12)
CRPSPD
Creep rate
Not used.
OFFSET
Offset value
Final moving distance. And the position will
be this value. If the value is positive, the
final moving is in the same direction of
homing. If it is negative the final moving will
be in the opposite of homing